This International Standard specifies a method for the secondary calibration of acoustic emission sensors as
receivers of elastic waves at the surface of a solid medium. The International Standard is applicable to laboratory
tertiary standard sensors and acoustic emission applications sensors.
The secondary calibration yields the frequency response of a sensor to waves of a type normally encountered in
acoustic emission work, namely Rayleigh waves. The source producing the signal used for the calibration is
mounted on the same surface of a test block as the sensor under test (SUT). The sensitivity of the sensor is
determined for excitation within the range of 100 kHz to 1 MHz. Sensitivity values are usually determined at
frequencies approximately 10 kHz apart. The units of the calibration are volts per unit of mechanical input
(displacement, velocity or acceleration).
Edition
1
Published Date
1999-07-15
Status
PUBLISHED
Pages
16
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This International Standard specifies a method for the secondary calibration of acoustic emission sensors as
receivers of elastic waves at the surface of a solid medium. The International Standard is applicable to laboratory
tertiary standard sensors and acoustic emission applications sensors.
The secondary calibration yields the frequency response of a sensor to waves of a type normally encountered in
acoustic emission work, namely Rayleigh waves. The source producing the signal used for the calibration is
mounted on the same surface of a test block as the sensor under test (SUT). The sensitivity of the sensor is
determined for excitation within the range of 100 kHz to 1 MHz. Sensitivity values are usually determined at
frequencies approximately 10 kHz apart. The units of the calibration are volts per unit of mechanical input
(displacement, velocity or acceleration).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 4006:1991 Measurement of fluid flow in closed conduits – Vocabulary and symbols
CDN $397.00 Add to cart -

ISO 14416:2003 Information and documentation – Requirements for binding of books, periodicals, serials and other paper documents for archive and library use – Methods and materials
CDN $310.00 Add to cart -

ISO 80004:2021 Nanotechnologies – Vocabulary – Part 6: Nano-object characterization
CDN $86.00 Add to cart -

ISO 22553:2019 Paints and varnishes – Electro-deposition coatings – Part 1: Vocabulary
CDN $86.00 Add to cart