ISO 12846:2012
ISO 12846:2012 Water quality – Determination of mercury – Method using atomic absorption spectrometry (AAS) with and without enrichment
CDN $195.00
Description
ISO 12846:2012 specifies two methods for the determination of mercury in drinking, surface, ground, rain and waste water after appropriate pre-digestion. For the first method, an enrichment step by amalgamation of the Hg on, for example, a gold/platinum adsorber is used. For the second method, the enrichment step is omitted.
The choice of method depends on the equipment available, the matrix and the concentration range of interest. Both methods are suitable for the determination of mercury in water. The method with enrichment commonly has a practical working range from 0,01 µg/l to 1 µg/l. The mean limit of quantification (LOQ) reported by the participants of the validation trial was 0,008 µg/l. This information on the LOQ gives the user of ISO 12846:2012 an orientation and does not replace the estimation of performance data from laboratory specific data. It has to be considered that it is possible to achieve lower LOQs with specific instrumentation (e.g. single mercury analysers).
The method without enrichment commonly has a practical working range starting at 0,05 µg/l. The LOQ reported by the participants of the validation trial was 0,024 µg/l. It is up to the user, based on the specific application, to decide whether higher concentrations are determined by omitting the enrichment step and/or by diluting the sample(s). The sensitivity of both methods is dependent on the selected operating conditions.
Another possibility for the determination of extremely low Hg concentrations down to 0,002 µg/l without pre-concentration is the application of atomic fluorescence spectrometry (see ISO 17852). Specific atomic-absorption mercury analysers allow determinations down to 0,010 µg/l without pre-concentration.
In general, the determination of trace concentrations of Hg by AAS (or AFS) is dependent on clean operating conditions in the laboratory and on the use of high-purity chemicals with negligible low-Hg blanks.
Note that ISO 12846:2012 may be applied to industrial and municipal waste water after an additional digestion step performed under appropriate conditions and after suitable method validation. A potential sample stability issue (mercury loss) for anaerobic reducing industrial effluents has to be considered thoroughly.
Edition
1
Published Date
2012-04-18
Status
PUBLISHED
Pages
15
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 12846:2012 specifies two methods for the determination of mercury in drinking, surface, ground, rain and waste water after appropriate pre-digestion. For the first method, an enrichment step by amalgamation of the Hg on, for example, a gold/platinum adsorber is used. For the second method, the enrichment step is omitted.
The choice of method depends on the equipment available, the matrix and the concentration range of interest. Both methods are suitable for the determination of mercury in water. The method with enrichment commonly has a practical working range from 0,01 µg/l to 1 µg/l. The mean limit of quantification (LOQ) reported by the participants of the validation trial was 0,008 µg/l. This information on the LOQ gives the user of ISO 12846:2012 an orientation and does not replace the estimation of performance data from laboratory specific data. It has to be considered that it is possible to achieve lower LOQs with specific instrumentation (e.g. single mercury analysers).
The method without enrichment commonly has a practical working range starting at 0,05 µg/l. The LOQ reported by the participants of the validation trial was 0,024 µg/l. It is up to the user, based on the specific application, to decide whether higher concentrations are determined by omitting the enrichment step and/or by diluting the sample(s). The sensitivity of both methods is dependent on the selected operating conditions.
Another possibility for the determination of extremely low Hg concentrations down to 0,002 µg/l without pre-concentration is the application of atomic fluorescence spectrometry (see ISO 17852). Specific atomic-absorption mercury analysers allow determinations down to 0,010 µg/l without pre-concentration.
In general, the determination of trace concentrations of Hg by AAS (or AFS) is dependent on clean operating conditions in the laboratory and on the use of high-purity chemicals with negligible low-Hg blanks.
Note that ISO 12846:2012 may be applied to industrial and municipal waste water after an additional digestion step performed under appropriate conditions and after suitable method validation. A potential sample stability issue (mercury loss) for anaerobic reducing industrial effluents has to be considered thoroughly.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5663:1984 Water quality – Determination of Kjeldahl nitrogen – Method after mineralization with selenium
CDN $86.00 Add to cart -

ISO 20236:2024 Water quality – Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb) and dissolved bound nitrogen (DNb) after high temperature catalytic oxidative combustion
CDN $263.00 Add to cart -

ISO 15586:2003 Water quality – Determination of trace elements using atomic absorption spectrometry with graphite furnace
CDN $263.00 Add to cart -

ISO 22066:2020 Water quality – Determination of total cyanide – Method using segmented flow injection, in-line ultraviolet digestion analysis by gas diffusion and amperometric detection
CDN $195.00 Add to cart