
ISO 12884:2000
ISO 12884:2000 Ambient air – Determination of total (gas and particle-phase) polycyclic aromatic hydrocarbons – Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses
CDN $259.00
Description
This International Standard specifies sampling, cleanup and analysis procedures for the determination of polycyclic
aromatic hydrocarbons (PAH) in ambient air. It is designed to collect both gas-phase and particulate-phase PAH
and to determine them collectively. It is a high-volume (100 l/min to 250 l/min) method capable of detecting
0,05 ng/m3 or lower concentrations of PAH with sampling volumes up to 350 m3. The method has been validated
for sampling periods up to 24 h.
Precision under normal conditions can be expected to be _ 25 % or better and uncertainty _ 50 % or better (see
annex A, Table A.1).
This International Standard describes a procedure for sampling and analysis for PAH that involves collection from
air on a combination fine-particle filter and sorbent trap, and subsequent analysis by gas chromatography/mass
spectrometry (GC/MS).
Edition
1
Published Date
2000-04-06
Status
PUBLISHED
Pages
27
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This International Standard specifies sampling, cleanup and analysis procedures for the determination of polycyclic
aromatic hydrocarbons (PAH) in ambient air. It is designed to collect both gas-phase and particulate-phase PAH
and to determine them collectively. It is a high-volume (100 l/min to 250 l/min) method capable of detecting
0,05 ng/m3 or lower concentrations of PAH with sampling volumes up to 350 m3. The method has been validated
for sampling periods up to 24 h.
Precision under normal conditions can be expected to be _ 25 % or better and uncertainty _ 50 % or better (see
annex A, Table A.1).
This International Standard describes a procedure for sampling and analysis for PAH that involves collection from
air on a combination fine-particle filter and sorbent trap, and subsequent analysis by gas chromatography/mass
spectrometry (GC/MS).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 13794:2019 Ambient air – Determination of asbestos fibres – Indirect-transfer transmission electron microscopy method
CDN $391.00 Add to cart -

ISO 16000:2014 Indoor air – Part 32: Investigation of buildings for the occurrence of pollutants
CDN $192.00 Add to cart -

ISO 22262:2016 Air quality – Bulk materials – Part 3: Quantitative determination of asbestos by X-ray diffraction method
CDN $347.00 Add to cart -

ISO 16000:2025 Indoor air – Part 22: Detection and quantification of fungal biomass by fungal Œ≤-N-acetylhexosaminidase enzyme activity
CDN $129.00 Add to cart







