Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 13160:2021

ISO 13160:2021 Water quality – Strontium 90 and strontium 89 – Test methods using liquid scintillation counting or proportional counting

CDN $336.00

SKU: 819bd68a526f Categories: ,

Description

This document specifies conditions for the determination of 90Sr and 89Sr activity concentration in samples of environmental water using liquid scintillation counting (LSC) or proportional counting (PC).

The method is applicable to test samples of drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample and a chemical separation are required to separate and purify strontium from a test portion of the sample.

The detection limit depends on the sample volume, the instrument used, the sample count time, the background count rate, the detection efficiency and the chemical yield. The method described in this document, using currently available LSC counters, has a detection limit of approximately 10 mBq l−1 and 2 mBq l−1 for 89Sr and 90Sr, respectively, which is lower than the WHO criteria for safe consumption of drinking water (100 Bq·l−1 for 89Sr and 10 Bq·l−1 for 90Sr)[3]. These values can be achieved with a counting time of 1 000 min for a sample volume of 2 l.

The methods described in this document are applicable in the event of an emergency situation. When fallout occurs following a nuclear accident, the contribution of 89Sr to the total amount of radioactive strontium is not negligible. This document provides test methods to determine the activity concentration of 90Sr in presence of 89Sr.

The analysis of 90Sr and 89Sr adsorbed to suspended matter is not covered by this method.

It is the user’s responsibility to ensure the validity of this test method selected for the water samples tested.

Edition

2

Published Date

2021-07-14

Status

PUBLISHED

Pages

41

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies conditions for the determination of 90Sr and 89Sr activity concentration in samples of environmental water using liquid scintillation counting (LSC) or proportional counting (PC).

The method is applicable to test samples of drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample and a chemical separation are required to separate and purify strontium from a test portion of the sample.

The detection limit depends on the sample volume, the instrument used, the sample count time, the background count rate, the detection efficiency and the chemical yield. The method described in this document, using currently available LSC counters, has a detection limit of approximately 10 mBq l−1 and 2 mBq l−1 for 89Sr and 90Sr, respectively, which is lower than the WHO criteria for safe consumption of drinking water (100 Bq·l−1 for 89Sr and 10 Bq·l−1 for 90Sr)[3]. These values can be achieved with a counting time of 1 000 min for a sample volume of 2 l.

The methods described in this document are applicable in the event of an emergency situation. When fallout occurs following a nuclear accident, the contribution of 89Sr to the total amount of radioactive strontium is not negligible. This document provides test methods to determine the activity concentration of 90Sr in presence of 89Sr.

The analysis of 90Sr and 89Sr adsorbed to suspended matter is not covered by this method.