ISO 13347:2004
ISO 13347:2004 Industrial fans – Determination of fan sound power levels under standardized laboratory conditions – Part 3: Enveloping surface methods
CDN $233.00
Description
ISO 13347-3:2004 applies to industrial fans as defined in ISO 5801 and ISO 13349. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined.
The sizes of fan which can be tested in accordance with ISO 13347-3:2004 are limited only by the practical aspects of the test set-up. Dimensional limitations, test fan dimensions, and air performance will control the room size, power and mounting requirements for the test fan.
The test arrangements in ISO 13347-3:2004 establish the laboratory conditions necessary for a successful test. Rarely will it be possible to meet these requirements in situ and ISO 13347-3:2004 is not intended for field measurements. Intending users are reminded that, in these situations, there may well be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.
The enveloping surface methods may be used for the determination of open inlet and/or open outlet sound power level of fans for standardized installation types.
An estimation (with increased uncertainty) of ducted sound power for fans too small, or otherwise inconvenient, for testing by the in-duct method described in ISO 5136 may also be obtained by the addition of end reflection corrections.
Edition
1
Published Date
2004-08-17
Status
PUBLISHED
Pages
22
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 13347-3:2004 applies to industrial fans as defined in ISO 5801 and ISO 13349. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined.
The sizes of fan which can be tested in accordance with ISO 13347-3:2004 are limited only by the practical aspects of the test set-up. Dimensional limitations, test fan dimensions, and air performance will control the room size, power and mounting requirements for the test fan.
The test arrangements in ISO 13347-3:2004 establish the laboratory conditions necessary for a successful test. Rarely will it be possible to meet these requirements in situ and ISO 13347-3:2004 is not intended for field measurements. Intending users are reminded that, in these situations, there may well be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.
The enveloping surface methods may be used for the determination of open inlet and/or open outlet sound power level of fans for standardized installation types.
An estimation (with increased uncertainty) of ducted sound power for fans too small, or otherwise inconvenient, for testing by the in-duct method described in ISO 5136 may also be obtained by the addition of end reflection corrections.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 612:1978 Road vehicles – Dimensions of motor vehicles and towed vehicles – Terms and definitions
CDN $173.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
CDN $115.00 Add to cart -

ISO 2574:1994 Aircraft – Electrical cables – Identification marking
CDN $115.00 Add to cart -

ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
CDN $233.00 Add to cart