Your cart is currently empty!

ISO 14708:2019
ISO 14708:2019 Implants for surgery – Active implantable medical devices – Part 7: Particular requirements for cochlear and auditory brainstem implant systems
CDN $351.00
Description
This document specifies requirements that are applicable to those active implantable medical devices that are intended to treat hearing impairment via electrical stimulation of the auditory pathways. Devices which treat hearing impairment via means other than electrical stimulation are not covered by this document.
The tests that are specified in this document are type tests and are to be carried out on samples of a device to show compliance.
This document is also applicable to non-implantable parts and accessories of the devices (see NOTE).
The electrical characteristics of the implantable part are determined by either the appropriate method detailed in this document or by any other method demonstrated to have an accuracy equal to, or better than, the method specified. In the case of dispute, the method detailed in this document applies.
NOTE A device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, this document specifies those requirements of non-implantable parts and accessories which could affect the safety or performance of the implantable part.
Edition
2
Published Date
2019-12-20
Status
PUBLISHED
Pages
68
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document specifies requirements that are applicable to those active implantable medical devices that are intended to treat hearing impairment via electrical stimulation of the auditory pathways. Devices which treat hearing impairment via means other than electrical stimulation are not covered by this document.
The tests that are specified in this document are type tests and are to be carried out on samples of a device to show compliance.
This document is also applicable to non-implantable parts and accessories of the devices (see NOTE).
The electrical characteristics of the implantable part are determined by either the appropriate method detailed in this document or by any other method demonstrated to have an accuracy equal to, or better than, the method specified. In the case of dispute, the method detailed in this document applies.
NOTE A device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, this document specifies those requirements of non-implantable parts and accessories which could affect the safety or performance of the implantable part.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 17117:2022 Health informatics – Terminological resources – Part 2: Implementation Capability (TIC)
0 out of 5CDN $115.00 Add to cart -
ISO 1991:1982 Vegetables – Nomenclature – First list
0 out of 5CDN $115.00 Add to cart -
ISO 21531:2009 Dentistry – Graphical symbols for dental instruments
0 out of 5CDN $173.00 Add to cart -
ISO 1990:1982 Fruits – Nomenclature – First list
0 out of 5CDN $115.00 Add to cart