Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 14851:2019

ISO 14851:2019 Determination of the ultimate aerobic biodegradability of plastic materials in an aqueous medium – Method by measuring the oxygen demand in a closed respirometer

CDN $263.00

Description

This document specifies a method, by measuring the oxygen demand in a closed respirometer, for the determination of the degree of aerobic biodegradability of plastic materials, including those containing formulation additives. The test material is exposed in an aqueous medium under laboratory conditions to an inoculum from activated sludge.

If an unadapted activated sludge is used as the inoculum, the test simulates the biodegradation processes which occur in a natural aqueous environment; if a mixed or pre-exposed inoculum is used, the method is used to investigate the potential biodegradability of a test material.

The conditions used in this document do not necessarily correspond to the optimum conditions allowing maximum biodegradation to occur, but this document is designed to determine the potential biodegradability of plastic materials or give an indication of their biodegradability in natural environments.

The method enables the assessment of the biodegradability to be improved by calculating a carbon balance (optional, see Annex E).

The method applies to the following materials.

– Natural and/or synthetic polymers, copolymers or mixtures thereof.

– Plastic materials which contain additives such as plasticizers, colorants or other compounds.

– Water-soluble polymers.

– Materials which, under the test conditions, do not inhibit the microorganisms present in the inoculum. Inhibitory effects can be determined using an inhibition control or by another appropriate method (see, for example, ISO 8192[2]). If the test material is inhibitory to the inoculum, a lower test concentration, another inoculum or a pre-exposed inoculum can be used.

Edition

2

Published Date

2019-03-07

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method, by measuring the oxygen demand in a closed respirometer, for the determination of the degree of aerobic biodegradability of plastic materials, including those containing formulation additives. The test material is exposed in an aqueous medium under laboratory conditions to an inoculum from activated sludge.

If an unadapted activated sludge is used as the inoculum, the test simulates the biodegradation processes which occur in a natural aqueous environment; if a mixed or pre-exposed inoculum is used, the method is used to investigate the potential biodegradability of a test material.

The conditions used in this document do not necessarily correspond to the optimum conditions allowing maximum biodegradation to occur, but this document is designed to determine the potential biodegradability of plastic materials or give an indication of their biodegradability in natural environments.

The method enables the assessment of the biodegradability to be improved by calculating a carbon balance (optional, see Annex E).

The method applies to the following materials.

- Natural and/or synthetic polymers, copolymers or mixtures thereof.

- Plastic materials which contain additives such as plasticizers, colorants or other compounds.

- Water-soluble polymers.

- Materials which, under the test conditions, do not inhibit the microorganisms present in the inoculum. Inhibitory effects can be determined using an inhibition control or by another appropriate method (see, for example, ISO 8192[2]). If the test material is inhibitory to the inoculum, a lower test concentration, another inoculum or a pre-exposed inoculum can be used.

Previous Editions

Can’t find what you are looking for?

Please contact us at: