Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

TEMA 2026 Edition – Online Subscription Only

$

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 15SIH, 2nd Edition: Installation and Handling of Spoolable Reinforced Plastic Line Pipe

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 754, 4th Edition: Process Safety Performance Indicators for the Refining and Petrochemical Industries

$

393

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2020: Power Piping

$

668

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2022: Power Piping

$

668

BUY NOW

ISO 14886:2014

ISO 14886:2014 Ships and marine technology – Large yachts – Structural fire protection for FRP yachts

CDN $130.00

SKU: be8db030ac8b Categories: ,

Description

ISO 14886:2014 applies to the structural fire protection of large FRP yachts of 24 m in length and over, and carrying up to 12 passengers. ISO 14886:2014 is not applicable to vessels subject to SOLAS.

By using the heat transfer Fourier Number, ISO 14886:2014 determines the equivalency of any proposed insulated FRP sandwich laminate to the model insulated sandwich laminate based on a fire tested insulated laminate approved in accordance with IMO FTP Code as a fire-resisting division.

The method considers the relevant mechanical, thermal, and physical properties of the insulation and the FRP laminate.

The technology of the elements of the insulation and FRP resistance to heat, smoke, and fire used in ISO 14886:2014 and the effectiveness of the insulation are applicable in general to insulated FRP as a fire-resistant material.

Edition

1

Published Date

2014-11-13

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 14886:2014 applies to the structural fire protection of large FRP yachts of 24 m in length and over, and carrying up to 12 passengers. ISO 14886:2014 is not applicable to vessels subject to SOLAS.

By using the heat transfer Fourier Number, ISO 14886:2014 determines the equivalency of any proposed insulated FRP sandwich laminate to the model insulated sandwich laminate based on a fire tested insulated laminate approved in accordance with IMO FTP Code as a fire-resisting division.

The method considers the relevant mechanical, thermal, and physical properties of the insulation and the FRP laminate.

The technology of the elements of the insulation and FRP resistance to heat, smoke, and fire used in ISO 14886:2014 and the effectiveness of the insulation are applicable in general to insulated FRP as a fire-resistant material.

Previous Editions

Can’t find what you are looking for?

Please contact us at: