ISO 15009:2016
ISO 15009:2016 Soil quality – Gas chromatographic determination of the content of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons – Purge-and-trap method with thermal desorption
CDN $251.00
Description
ISO 15009:2016 specifies a method for quantitative gas-chromatographic determination of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons in soil.
This International Standard is applicable to all types of soil.
NOTE In the case of unsaturated peaty soils, absorption of the extraction solution may occur.
The lower limit of quantification is dependent on the equipment used and the quality of the methanol grade used for the extraction of the soil sample.
Under the conditions specified in this International Standard the following limits of quantification apply (expressed on basis of dry matter):
Typical limit of quantification when using GC-FID:
– Volatile aromatic hydrocarbons: 0,1 mg/kg
Typical limit of quantification when using GC-ECD:
– Volatile halogenated hydrocarbons: 0,01 mg/kg
Lower limits of quantification for some compounds can be achieved by using mass spectrometry (MS) with selected ion detection.
Edition
3
Published Date
2016-02-12
Status
PUBLISHED
Pages
20
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 15009:2016 specifies a method for quantitative gas-chromatographic determination of volatile aromatic hydrocarbons, naphthalene and volatile halogenated hydrocarbons in soil.
This International Standard is applicable to all types of soil.
NOTE In the case of unsaturated peaty soils, absorption of the extraction solution may occur.
The lower limit of quantification is dependent on the equipment used and the quality of the methanol grade used for the extraction of the soil sample.
Under the conditions specified in this International Standard the following limits of quantification apply (expressed on basis of dry matter):
Typical limit of quantification when using GC-FID:
- Volatile aromatic hydrocarbons: 0,1 mg/kg
Typical limit of quantification when using GC-ECD:
- Volatile halogenated hydrocarbons: 0,01 mg/kg
Lower limits of quantification for some compounds can be achieved by using mass spectrometry (MS) with selected ion detection.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 13914:2023 Soil, treated biowaste and sludge – Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with high resolution mass selective detection (HR GC-MS)
CDN $336.00 Add to cart -

ISO 18227:2014 Soil quality – Determination of elemental composition by X-ray fluorescence
CDN $336.00 Add to cart -

ISO 10390:2021 Soil, treated biowaste and sludge – Determination of pH
CDN $124.00 Add to cart -

ISO 12404:2021 Soil and waste – Guidance on the selection and application of screening methods
CDN $251.00 Add to cart