Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 15202:2004

ISO 15202:2004 Workplace air – Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry – Part 3: Analysis

CDN $312.00

Description

ISO 15202-3:2004 prescribes a procedure for the use of inductively coupled plasma atomic emission spectrometry for analysing test solutions prepared as prescribed in ISO 15202-2 from samples of airborne particulate matter collected as prescribed in ISO 15202-1. Method development, performance checks and a routine analysis method are prescribed.

The procedure suffers from no significant spectral interferences, provided that suitable analytical wavelengths are used. However, inaccurate background correction and/or inadequate matrix-matching can adversely affect results.

ISO 15202-3:2004 is applicable to the following non-exclusive list of metals and metalloids for which limit values have been set; however, there is no information available on the effectiveness of any of the sample dissolution methods specified in ISO 15202-2 for those elements in italics:

aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, caesium, cadmium, calcium, chromium, cobalt, copper, hafnium, indium, iron, lead, lithium, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, platinum, potassium, rhodium, selenium, silver, sodium, strontium, tantalum, tellurium, thallium, tin, titanium, tungsten, uranium, vanadium, yttrium, zinc and zirconium.

ISO 15202-3:2004 is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.

The results obtained may be used for the assessment of workplace exposure to metals and metalloids for comparison with limit values.

Edition

1

Published Date

2004-11-23

Status

PUBLISHED

Pages

37

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 15202-3:2004 prescribes a procedure for the use of inductively coupled plasma atomic emission spectrometry for analysing test solutions prepared as prescribed in ISO 15202-2 from samples of airborne particulate matter collected as prescribed in ISO 15202-1. Method development, performance checks and a routine analysis method are prescribed.

The procedure suffers from no significant spectral interferences, provided that suitable analytical wavelengths are used. However, inaccurate background correction and/or inadequate matrix-matching can adversely affect results.

ISO 15202-3:2004 is applicable to the following non-exclusive list of metals and metalloids for which limit values have been set; however, there is no information available on the effectiveness of any of the sample dissolution methods specified in ISO 15202-2 for those elements in italics:

aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, caesium, cadmium, calcium, chromium, cobalt, copper, hafnium, indium, iron, lead, lithium, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, platinum, potassium, rhodium, selenium, silver, sodium, strontium, tantalum, tellurium, thallium, tin, titanium, tungsten, uranium, vanadium, yttrium, zinc and zirconium.

ISO 15202-3:2004 is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.

The results obtained may be used for the assessment of workplace exposure to metals and metalloids for comparison with limit values.

Previous Editions

Can’t find what you are looking for?