
ISO 15586:2003
ISO 15586:2003 Water quality – Determination of trace elements using atomic absorption spectrometry with graphite furnace
CDN $263.00
Description
ISO 15586:2003 includes principles and procedures for the determination of trace levels of: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, and Zn in surface water, ground water, drinking water, wastewater and sediments, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable to the determination of low concentrations of elements.
The detection limit of the method for each element depends on the sample matrix as well as of the instrument, the type of atomizer and the use of chemical modifiers. For water samples with a simple matrix (i.e. low concentration of dissolved solids and particles), the method detection limits will be close to instrument detection limits. The minimum acceptable detection limit values for a 20-microlitre sample volume are specified.
Edition
1
Published Date
2003-10-08
Status
PUBLISHED
Pages
23
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 15586:2003 includes principles and procedures for the determination of trace levels of: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, and Zn in surface water, ground water, drinking water, wastewater and sediments, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable to the determination of low concentrations of elements.
The detection limit of the method for each element depends on the sample matrix as well as of the instrument, the type of atomizer and the use of chemical modifiers. For water samples with a simple matrix (i.e. low concentration of dissolved solids and particles), the method detection limits will be close to instrument detection limits. The minimum acceptable detection limit values for a 20-microlitre sample volume are specified.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22478:2006 Water quality – Determination of certain explosives and related compounds – Method using high-performance liquid chromatography (HPLC) with UV detection
CDN $263.00 Add to cart -

ISO 14911:1998 Water quality – Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography – Method for water and waste water
CDN $195.00 Add to cart -

ISO 21793:2020 Water quality – Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb), dissolved bound nitrogen (DNb), total bound phosphorus (TPb) and dissolved bound phosphorus (DPb) after wet chemical catalysed ozone hydroxyl radical oxidation (COHR)
CDN $310.00 Add to cart -

ISO 21675:2019 Water quality – Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water – Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
CDN $352.00 Add to cart







