Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 15690:2013

ISO 15690:2013 Radiological protection – Recommendations for dealing with discrepancies between personal dosimeter systems used in parallel

CDN $124.00

SKU: ae303fcf96d9 Category:

Description

ISO 15690:2013 provides recommendations for dealing with discrepancies between dosimeter systems used in parallel, in order to comply with established criteria and national regulations.

ISO 15690:2013 gives guidelines for investigating and analysing the discrepancies between the results of personal dosimetry systems, using two or more dosimeters (often one passive dosimeter and one active dosimeter), worn in parallel by the same worker.

ISO 15690:2013 identifies when the difference between measurements made by personal dosimetry systems used in parallel is considered significant and, hence, needs to be investigated.

It specifies the treatment of this difference.

In ISO 15690:2013, only the personal dose equivalent, Hp(10), from photon radiation is considered. Exposure to beta particles and neutrons might need to be taken into account when identified discrepancies are investigated.

ISO 15690:2013 applies to situations where the period of wearing can be integrated to the same period of time for both systems.

Edition

1

Published Date

2013-06-03

Status

PUBLISHED

Pages

11

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 15690:2013 provides recommendations for dealing with discrepancies between dosimeter systems used in parallel, in order to comply with established criteria and national regulations.

ISO 15690:2013 gives guidelines for investigating and analysing the discrepancies between the results of personal dosimetry systems, using two or more dosimeters (often one passive dosimeter and one active dosimeter), worn in parallel by the same worker.

ISO 15690:2013 identifies when the difference between measurements made by personal dosimetry systems used in parallel is considered significant and, hence, needs to be investigated.

It specifies the treatment of this difference.

In ISO 15690:2013, only the personal dose equivalent, Hp(10), from photon radiation is considered. Exposure to beta particles and neutrons might need to be taken into account when identified discrepancies are investigated.

ISO 15690:2013 applies to situations where the period of wearing can be integrated to the same period of time for both systems.

Previous Editions

Can’t find what you are looking for?

Please contact us at: