ISO 15713:2006
ISO 15713:2006 Stationary source emissions – Sampling and determination of gaseous fluoride content
CDN $173.00
Description
ISO 15713:2006 is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydrogen fluoride in the stack gas.
ISO 15713:2006 is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded as valid. The detection limit of the method is estimated as 0,1 mg m-3, based on a sample volume of 0,1 m3. All compounds that are volatile at the filtration temperature and produce soluble fluoride compounds upon reaction with water are measured by this method. The method does not measure fluorocarbons. The concentration of fluoride in the adsorbent solution is then measured using an ion selective electrode. The amount of fluoride measured is then expressed as hydrogen fluoride by convention, though this may not reflect the chemical nature of the compounds, which are measured.
Edition
1
Published Date
2006-06-09
Status
PUBLISHED
Pages
14
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 15713:2006 is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydrogen fluoride in the stack gas.
ISO 15713:2006 is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded as valid. The detection limit of the method is estimated as 0,1 mg m-3, based on a sample volume of 0,1 m3. All compounds that are volatile at the filtration temperature and produce soluble fluoride compounds upon reaction with water are measured by this method. The method does not measure fluorocarbons. The concentration of fluoride in the adsorbent solution is then measured using an ion selective electrode. The amount of fluoride measured is then expressed as hydrogen fluoride by convention, though this may not reflect the chemical nature of the compounds, which are measured.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 18466:2016 Stationary source emissions – Determination of the biogenic fraction in CO2 in stack gas using the balance method
CDN $233.00 Add to cart -

ISO 19694:2023 Stationary source emissions – Determination of greenhouse gas emissions in energy-intensive industries – Part 5: Lime industry
CDN $351.00 Add to cart -

ISO 10849:2022 Stationary source emissions – Determination of the mass concentration of nitrogen oxides in flue gas – Performance characteristics of automated measuring systems
CDN $312.00 Add to cart -

ISO 19694:2023 Stationary source emissions – Determination of greenhouse gas emissions in energy-intensive industries – Part 6: Ferroalloys and silicon industry
CDN $233.00 Add to cart