REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 12R1: Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service

$

285

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report 2583 – Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API Bulletin 592 – Elements of a Fixed Equipment Mechanical Integrity (FE MI) Program

$

142

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC Q1: Addenda 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

ISO 15714:2019

ISO 15714:2019 Method of evaluating the UV dose to airborne microorganisms transiting in-duct ultraviolet germicidal irradiation devices

CDN $173.00

SKU: 876a70a4e9d2 Category:

Description

This document describes a method in laboratory to assess the performance of ultraviolet germicidal irradiation (UVGI) devices which will be mounted in-duct in heating, ventilating and air-conditioning (HVAC) systems.

The method includes the detailed requirements for test rig, microorganisms, procedures, data calculation and result report to determine the UV dose to model microorganisms by an UVGI device at several airflow rates. By the testing results, the capacity of in-duct UVGI devices for air disinfection can be evaluated and compared reliably.

If the susceptibility constant of a given microorganism is known, the inactivation rate of that micro-organism by the tested UVGI devices can be further calculated.

Edition

1

Published Date

2019-07-12

Status

PUBLISHED

Pages

17

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document describes a method in laboratory to assess the performance of ultraviolet germicidal irradiation (UVGI) devices which will be mounted in-duct in heating, ventilating and air-conditioning (HVAC) systems.

The method includes the detailed requirements for test rig, microorganisms, procedures, data calculation and result report to determine the UV dose to model microorganisms by an UVGI device at several airflow rates. By the testing results, the capacity of in-duct UVGI devices for air disinfection can be evaluated and compared reliably.

If the susceptibility constant of a given microorganism is known, the inactivation rate of that micro-organism by the tested UVGI devices can be further calculated.