ISO 15923:2017
ISO 15923:2017 Water quality – Determination of selected parameters by discrete analysis systems – Part 2: Chromium(VI), fluoride, total alkalinity, total hardness, calcium, magnesium, iron, iron(II), manganese and aluminium with photometric detection
CDN $273.00
Description
ISO/TS 15923-2:2017 specifies methods for the automatic determination of chromium(VI), fluoride, total alkalinity, total hardness, calcium, magnesium, iron, iron(II), manganese and aluminium with photometric determination using a discrete analysis system. The field of application is water (ground, potable, surface, waste, eluates and boiler water). The method can also be applied to marine waters with matrix matching of standard and control solutions. Note that some parameters, notably iron, manganese and aluminium and possibly chromium(VI), calcium and magnesium may not be completely quantified if the sample contains particulates. Samples can be digested in acid, as long as the buffering capacity of the reaction mixture is not exceeded. Such procedures are beyond the scope of ISO/TS 15923-2:2017, which is best suited to the determination of dissolved metals following on-site filtration.
Edition
1
Published Date
2017-09-29
Status
PUBLISHED
Pages
31
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO/TS 15923-2:2017 specifies methods for the automatic determination of chromium(VI), fluoride, total alkalinity, total hardness, calcium, magnesium, iron, iron(II), manganese and aluminium with photometric determination using a discrete analysis system. The field of application is water (ground, potable, surface, waste, eluates and boiler water). The method can also be applied to marine waters with matrix matching of standard and control solutions. Note that some parameters, notably iron, manganese and aluminium and possibly chromium(VI), calcium and magnesium may not be completely quantified if the sample contains particulates. Samples can be digested in acid, as long as the buffering capacity of the reaction mixture is not exceeded. Such procedures are beyond the scope of ISO/TS 15923-2:2017, which is best suited to the determination of dissolved metals following on-site filtration.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5663:1984 Water quality – Determination of Kjeldahl nitrogen – Method after mineralization with selenium
CDN $76.00 Add to cart -

ISO 15680:2003 Water quality – Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
CDN $273.00 Add to cart -

ISO 16265:2009 Water quality – Determination of the methylene blue active substances (MBAS) index – Method using continuous flow analysis (CFA)
CDN $115.00 Add to cart -

ISO 22066:2020 Water quality – Determination of total cyanide – Method using segmented flow injection, in-line ultraviolet digestion analysis by gas diffusion and amperometric detection
CDN $173.00 Add to cart