Your cart is currently empty!

ISO 15970:2008
ISO 15970:2008 Natural gas – Measurement of properties – Volumetric properties: density, pressure, temperature and compression factor
CDN $312.00
Description
ISO 15970:2008 gives requirements and procedures for the measurement of the properties of natural gas that are used mainly for volume calculation and volume conversion: density at reference and at operating conditions, pressure, temperature and compression factor.
Only those methods and instruments are considered that are suitable for field operation under the conditions of natural gas transmission and distribution, installed either in-line or on-line, and that do not involve the determination of the gas composition.
ISO 15970:2008 gives examples for currently used instruments that are available commercially and of interest to the natural gas industry.
The density at reference conditions (sometimes referred to as normal, standard or even base density) is required for conversion of volume data and can be used for other physical properties.
Density at operating conditions is measured for mass-flow measurement and volume conversion using the observed line density and can be used for other physical properties. ISO 15970:2008 covers density transducers based on vibrating elements, normally suitable for measuring ranges of 5 kg/m3 to 250 kg/m3.
Pressure measurement deals with differential, gauge and absolute pressure transmitters. It considers both analogue and smart transmitters (i.e. microprocessor based instruments) and, if not specified otherwise, the corresponding paragraphs refer to differential, absolute and gauge pressure transmitters without distinction.
Temperature measurements in natural gas are performed within the range of conditions under which transmission and distribution are normally carried out (253 K < T < 338 K). In this field of application, resistance thermometer detectors (RTD) are generally used.
The compression factor (also known as the compressibility factor or the real gas factor and given the symbol Z) appears, in particular, in equations governing volumetric metering. Moreover, the conversion of volume at metering conditions to volume at defined reference conditions can properly proceed with an accurate knowledge of Z at both relevant pressure and relevant temperature conditions.
Edition
1
Published Date
2008-06-09
Status
PUBLISHED
Pages
47
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 15970:2008 gives requirements and procedures for the measurement of the properties of natural gas that are used mainly for volume calculation and volume conversion: density at reference and at operating conditions, pressure, temperature and compression factor.
Only those methods and instruments are considered that are suitable for field operation under the conditions of natural gas transmission and distribution, installed either in-line or on-line, and that do not involve the determination of the gas composition.
ISO 15970:2008 gives examples for currently used instruments that are available commercially and of interest to the natural gas industry.
The density at reference conditions (sometimes referred to as normal, standard or even base density) is required for conversion of volume data and can be used for other physical properties.
Density at operating conditions is measured for mass-flow measurement and volume conversion using the observed line density and can be used for other physical properties. ISO 15970:2008 covers density transducers based on vibrating elements, normally suitable for measuring ranges of 5 kg/m3 to 250 kg/m3.
Pressure measurement deals with differential, gauge and absolute pressure transmitters. It considers both analogue and smart transmitters (i.e. microprocessor based instruments) and, if not specified otherwise, the corresponding paragraphs refer to differential, absolute and gauge pressure transmitters without distinction.
Temperature measurements in natural gas are performed within the range of conditions under which transmission and distribution are normally carried out (253 K < T < 338 K). In this field of application, resistance thermometer detectors (RTD) are generally used.
The compression factor (also known as the compressibility factor or the real gas factor and given the symbol Z) appears, in particular, in equations governing volumetric metering. Moreover, the conversion of volume at metering conditions to volume at defined reference conditions can properly proceed with an accurate knowledge of Z at both relevant pressure and relevant temperature conditions.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 2612:2023 Analysis of natural gas – Biomethane – Determination of ammonia content by tuneable diode laser absorption spectroscopy
0 out of 5CDN $115.00 Add to cart -
ISO 12213:2006 Natural gas – Calculation of compression factor – Part 1: Introduction and guidelines
0 out of 5CDN $173.00 Add to cart -
ISO 2620:2024 Analysis of natural gas – Biomethane – Determination of VOCs by thermal desorption gas chromatography with flame ionization and/or mass spectrometry detectors
0 out of 5CDN $115.00 Add to cart -
ISO 2614:2023 Analysis of natural gas – Biomethane – Determination of terpenes’ content by micro gas chromatography
0 out of 5CDN $115.00 Add to cart