Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 16000:2014

ISO 16000:2014 Indoor air – Part 30: Sensory testing of indoor air

CDN $295.00

SKU: 13d2eb7a7838 Category:

Description

ISO 16000-30:2014 specifies sensory testing and the evaluation of indoor odours using human panels. Sensory testing can be performed on site or in laboratories; in the latter case, by means of air in sampling containers which were collected from the site.

The olfactory testing is appropriate for office and administration buildings, assembly halls, residential buildings, and other habitable rooms in which the comfort and health of the occupants is of interest. The test criteria in ISO 16000-30:2014 specifies are not applicable to factory buildings and workshops or other rooms in which odours unavoidably stem from the production processes (kitchens, bakeries etc.). If an odour evaluation of such rooms is undertaken without the odour-producing processes, it is necessary to take into account that there is a possibility that the processes have influenced and changed the odour of the room through the adsorption of odorous compounds.

Sensory odour tests of indoor air can meet a variety of objectives. These include finding the cause(s) of unpleasant or objectionable odours, determining the reasonability of odours and the usability of affected rooms, and inspecting the results of renovation work. When seeking the cause of odours, it is wise to conduct additional laboratory tests on samples of the component materials according to ISO 16000‚Äë28. In the process of locating odour sources by means of olfactory tests, it is necessary to take into account the fact that the odour compounds can accumulate on other surfaces, which exacerbates the problem.

Edition

1

Published Date

2014-08-21

Status

PUBLISHED

Pages

31

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 16000-30:2014 specifies sensory testing and the evaluation of indoor odours using human panels. Sensory testing can be performed on site or in laboratories; in the latter case, by means of air in sampling containers which were collected from the site.

The olfactory testing is appropriate for office and administration buildings, assembly halls, residential buildings, and other habitable rooms in which the comfort and health of the occupants is of interest. The test criteria in ISO 16000-30:2014 specifies are not applicable to factory buildings and workshops or other rooms in which odours unavoidably stem from the production processes (kitchens, bakeries etc.). If an odour evaluation of such rooms is undertaken without the odour-producing processes, it is necessary to take into account that there is a possibility that the processes have influenced and changed the odour of the room through the adsorption of odorous compounds.

Sensory odour tests of indoor air can meet a variety of objectives. These include finding the cause(s) of unpleasant or objectionable odours, determining the reasonability of odours and the usability of affected rooms, and inspecting the results of renovation work. When seeking the cause of odours, it is wise to conduct additional laboratory tests on samples of the component materials according to ISO 16000‚Äë28. In the process of locating odour sources by means of olfactory tests, it is necessary to take into account the fact that the odour compounds can accumulate on other surfaces, which exacerbates the problem.

Previous Editions

Can’t find what you are looking for?

Please contact us at: