
ISO 16014:2019
ISO 16014:2019 Plastics – Determination of average molecular weight and molecular weight distribution of polymers using size-exclusion chromatography – Part 5: Light-scattering method
CDN $233.00
Description
This document specifies a general method for determining the average molecular weight and the molecular weight distribution of polymers using SEC-LS, i.e. size-exclusion chromatography coupled with light-scattering detection. The average molecular weight and the molecular weight distribution are calculated from molecular weight data and weight concentrations determined continuously with elution time. The molecular weight at each elution time is determined absolutely by combining a light-scattering detector with a concentration-sensitive detector. Therefore, SEC-LS is classified as an absolute method.
This method is applicable to linear homopolymers and to nonlinear homopolymers such as branched, star-shaped, comb-like, stereo-regular and stereo-irregular polymers. It can also be applied to heterophasic copolymers whose molecular composition cannot vary. However, SEC-LS is not applicable to block, graft or heterophasic copolymers whose molecular composition can vary. And the methods are applicable to molecular weights ranging from that of the monomer to 3 000 000, but are not intended for samples that contain > 30 % of components having a molecular weight < 1 000.
Edition
2
Published Date
2019-05-15
Status
PUBLISHED
Pages
24
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a general method for determining the average molecular weight and the molecular weight distribution of polymers using SEC-LS, i.e. size-exclusion chromatography coupled with light-scattering detection. The average molecular weight and the molecular weight distribution are calculated from molecular weight data and weight concentrations determined continuously with elution time. The molecular weight at each elution time is determined absolutely by combining a light-scattering detector with a concentration-sensitive detector. Therefore, SEC-LS is classified as an absolute method.
This method is applicable to linear homopolymers and to nonlinear homopolymers such as branched, star-shaped, comb-like, stereo-regular and stereo-irregular polymers. It can also be applied to heterophasic copolymers whose molecular composition cannot vary. However, SEC-LS is not applicable to block, graft or heterophasic copolymers whose molecular composition can vary. And the methods are applicable to molecular weights ranging from that of the monomer to 3 000 000, but are not intended for samples that contain > 30 % of components having a molecular weight < 1 000.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22766:2020 Plastics – Determination of the degree of disintegration of plastic materials in marine habitats under real field conditions
CDN $173.00 Add to cart -

ISO 11907:1998 Plastics – Smoke generation – Determination of the corrosivity of fire effluents – Part 4: Dynamic decomposition method using a conical radiant heater
CDN $233.00 Add to cart -

ISO 22526:2020 Plastics – Carbon and environmental footprint of biobased plastics – Part 2: Material carbon footprint, amount (mass) of CO2 removed from the air and incorporated into polymer molecule
CDN $115.00 Add to cart -

ISO 472:2018 Plastics – Vocabulary – Amendment 1: Additional items
CDN $76.00 Add to cart







