Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 16063:2014

ISO 16063:2014 Methods for the calibration of vibration and shock transducers – Part 16: Calibration by Earth’s gravitation

CDN $131.00

Description

ISO 16063-16:2014 specifies the instrumentation and procedure to be used for performing primary calibration of accelerometers using Earth’s gravitation. It is applicable to rectilinear accelerometers with DC (zero hertz frequency) response, such as straingauge, piezoresistive, variable capacitance, and servo accelerometer types.

ISO 16063-16:2014 is applicable to the calibration of the magnitude of the sensitivity, referenced to the acceleration due to the local gravitation at 0 Hz.

With the use of appropriate calibration equipment, ISO 16063-16:2014 can be applied to the calibration of the magnitude of the sensitivity, referenced to fractional parts of the acceleration due to the local gravitation at 0 Hz. The specification of the instrumentation used contains requirements on environmental conditions, as well as specific requirements for the apparatus to be used.

Edition

1

Published Date

2014-05-30

Status

PUBLISHED

Pages

11

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 16063-16:2014 specifies the instrumentation and procedure to be used for performing primary calibration of accelerometers using Earth's gravitation. It is applicable to rectilinear accelerometers with DC (zero hertz frequency) response, such as straingauge, piezoresistive, variable capacitance, and servo accelerometer types.

ISO 16063-16:2014 is applicable to the calibration of the magnitude of the sensitivity, referenced to the acceleration due to the local gravitation at 0 Hz.

With the use of appropriate calibration equipment, ISO 16063-16:2014 can be applied to the calibration of the magnitude of the sensitivity, referenced to fractional parts of the acceleration due to the local gravitation at 0 Hz. The specification of the instrumentation used contains requirements on environmental conditions, as well as specific requirements for the apparatus to be used.

Previous Editions

Can’t find what you are looking for?

Please contact us at: