REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16B Coiled Tubing, Snubbing and Wireline Well Intervention Equipment

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing w/ Addendum 1

$

518

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1161: Hazardous Liquid Pipeline Operator Qualification (OQ) : Edition 6

$

301

BUY NOW

ISO 16140:2019

ISO 16140:2019 Microbiology of the food chain – Method validation – Part 6: Protocol for the validation of alternative (proprietary) methods for microbiological confirmation and typing procedures

CDN $233.00

SKU: cad20624291c Category:

Description

This document specifies the general principle and the technical protocol for the validation of alternative confirmation methods for microbiology in the food chain. This document compares the result of the alternative confirmation method against the confirmation procedure of a reference method or, if needed, a reference confirmation method (e.g. whole genome sequencing).

This document is applicable to the validation of alternative confirmation methods used for the analysis (detection or quantification) of isolated microorganisms in:

– products intended for human consumption;

– products intended for animal feeding;

– environmental samples in the area of food and feed production, handling;

– samples from the primary production stage.

Validated alternative confirmation methods can be used to replace (partly or completely) the confirmation procedure described in:

– the reference method;

– an alternative method validated in accordance with ISO 16140-2 only if one of the isolation agars specified in the validation study of the alternative confirmation method is used.

This document is also applicable to the validation of alternative typing methods, where the reference method can be, for example, a serological method (e.g. serotyping of Salmonella) or a molecular method (e.g. typing of Shiga toxin-producing E. coli).

This document is, in particular, applicable to bacteria and fungi. Some clauses can be applicable to other (micro)organisms, to be determined on a case-by-case basis.

Validation studies in accordance with this document are primarily intended to be performed by organizations or expert laboratories involved in method validation, but can also be used by a single laboratory, especially when performing in-house validation under certain conditions (see ISO 16140-4).

Edition

1

Published Date

2019-11-12

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the general principle and the technical protocol for the validation of alternative confirmation methods for microbiology in the food chain. This document compares the result of the alternative confirmation method against the confirmation procedure of a reference method or, if needed, a reference confirmation method (e.g. whole genome sequencing).

This document is applicable to the validation of alternative confirmation methods used for the analysis (detection or quantification) of isolated microorganisms in:

- products intended for human consumption;

- products intended for animal feeding;

- environmental samples in the area of food and feed production, handling;

- samples from the primary production stage.

Validated alternative confirmation methods can be used to replace (partly or completely) the confirmation procedure described in:

- the reference method;

- an alternative method validated in accordance with ISO 16140-2 only if one of the isolation agars specified in the validation study of the alternative confirmation method is used.

This document is also applicable to the validation of alternative typing methods, where the reference method can be, for example, a serological method (e.g. serotyping of Salmonella) or a molecular method (e.g. typing of Shiga toxin-producing E. coli).

This document is, in particular, applicable to bacteria and fungi. Some clauses can be applicable to other (micro)organisms, to be determined on a case-by-case basis.

Validation studies in accordance with this document are primarily intended to be performed by organizations or expert laboratories involved in method validation, but can also be used by a single laboratory, especially when performing in-house validation under certain conditions (see ISO 16140-4).