ISO 16362:2005 Ambient air – Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography
CDN $310.00
Description
ISO 16362:2005 specifies sampling, cleanup and analysis procedures for the quantitative determination of low volatility (particle-bound) polycyclic aromatic hydrocarbons (PAHs) in ambient air. For sampling, a low-volume or a medium/high-volume sampling device may be used. Sampling times between 1 h and 24 h are possible. The sampling volume flow rates can range from 1 m/h to 4 m/h (“low volume sampler”) or from 10 m/h to about 90 m/h (“medium/high-volume sampler”). In any case, the linear face velocity at the collection filter should range between about 0,5 m/s and 0,9 m/s.
The method has been validated for sampling periods up to 24 h. The detection limits for single PAHs and the standard deviations resulting from duplicate measurements are listed.
ISo 16362:2005 describes a sampling and analysis procedure for PAH that involves collection from air onto a filter followed by analysis using high performance liquid chromatography usually with fluorescence detector (FLD). The use of a diode array detector (DAD) is possible. The combination of both detector types is also possible. Total suspended particulate matter is sampled.
Generally, compounds having a boiling point above 430 °C (vapour pressure less than 10-9 kPa at 25 °C, e.g. chrysene, benz[a]anthracene) can be collected efficiently on the filter at low ambient temperatures (e.g. below 10 °C). In contrast, at higher temperatures (above 30 °C, see also ISO 12884[1]), only PAHs having boiling points above 475 °C (vapour pressure less than 10-10 kPa at 25 °C) are determined quantitatively.
Edition
1
Published Date
2005-02-18
Status
PUBLISHED
Pages
27
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 16362:2005 specifies sampling, cleanup and analysis procedures for the quantitative determination of low volatility (particle-bound) polycyclic aromatic hydrocarbons (PAHs) in ambient air. For sampling, a low-volume or a medium/high-volume sampling device may be used. Sampling times between 1 h and 24 h are possible. The sampling volume flow rates can range from 1 m/h to 4 m/h ("low volume sampler") or from 10 m/h to about 90 m/h ("medium/high-volume sampler"). In any case, the linear face velocity at the collection filter should range between about 0,5 m/s and 0,9 m/s.
The method has been validated for sampling periods up to 24 h. The detection limits for single PAHs and the standard deviations resulting from duplicate measurements are listed.
ISo 16362:2005 describes a sampling and analysis procedure for PAH that involves collection from air onto a filter followed by analysis using high performance liquid chromatography usually with fluorescence detector (FLD). The use of a diode array detector (DAD) is possible. The combination of both detector types is also possible. Total suspended particulate matter is sampled.
Generally, compounds having a boiling point above 430 °C (vapour pressure less than 10-9 kPa at 25 °C, e.g. chrysene, benz[a]anthracene) can be collected efficiently on the filter at low ambient temperatures (e.g. below 10 °C). In contrast, at higher temperatures (above 30 °C, see also ISO 12884[1]), only PAHs having boiling points above 475 °C (vapour pressure less than 10-10 kPa at 25 °C) are determined quantitatively.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16017:2000 Indoor, ambient and workplace air – Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography – Part 1: Pumped sampling
CDN $310.00 Add to cart -

ISO 11665:2017 Measurement of radioactivity in the environment – Air: radon 222 – Part 13: Determination of the diffusion coefficient in waterproof materials: membrane two-side activity concentration test method
CDN $336.00 Add to cart -

ISO 11665:2019 Measurement of radioactivity in the environment – Air: radon-222 – Part 1: Origins of radon and its short-lived decay products and associated measurement methods
CDN $310.00 Add to cart -

ISO 20045:2023 Measurement of the radioactivity in the environment – Air: tritium – Test method using bubbler sampling
CDN $310.00 Add to cart