Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 1663:2023

ISO 1663:2023 Rigid cellular plastics – Determination of water vapour transmission properties

CDN $173.00

SKU: c6d5bb35423c Category:

Description

This document specifies a method of determining the water vapour transmission rate, water vapour permeance, water vapour permeability and water vapour diffusion resistance index for rigid cellular plastics.

This method is applicable for the testing of rigid cellular materials that have thicknesses from 10 mm upwards and can, as an integral part of the material, contain natural skins or adhered facings of some different material.

Three different sets of temperature and humidity conditions are provided, as follows:

a)       38 °C and a relative-humidity gradient across the test specimen of 0 % to 88 %

b)       23 °C and a relative-humidity gradient across the test specimen of 0 % to 85 %

c)        23 °C and a relative-humidity gradient across the test specimen of 0 % to of 50 %

The results obtained by this method are suitable for design purposes and production control, and for inclusion in product specifications.

The method is suitable for materials which have water vapour transmission rates in the range 3 µg/(m2⋅s) to 1 400 µg/(m2⋅s).

Edition

4

Published Date

2023-08-08

Status

PUBLISHED

Pages

16

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method of determining the water vapour transmission rate, water vapour permeance, water vapour permeability and water vapour diffusion resistance index for rigid cellular plastics.

This method is applicable for the testing of rigid cellular materials that have thicknesses from 10 mm upwards and can, as an integral part of the material, contain natural skins or adhered facings of some different material.

Three different sets of temperature and humidity conditions are provided, as follows:

a)       38 °C and a relative-humidity gradient across the test specimen of 0 % to 88 %

b)       23 °C and a relative-humidity gradient across the test specimen of 0 % to 85 %

c)        23 °C and a relative-humidity gradient across the test specimen of 0 % to of 50 %

The results obtained by this method are suitable for design purposes and production control, and for inclusion in product specifications.

The method is suitable for materials which have water vapour transmission rates in the range 3 µg/(m2⋅s) to 1 400 µg/(m2⋅s).

Previous Editions

Can’t find what you are looking for?

Please contact us at: