Search
×
FR

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 21316:2026 Traditional Chinese medicine — Isatis indigotica root

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

TEMA 11th Edition – Book of Standards (Not for Resale)

$

0

BUY NOW

ISO 16637:2016

ISO 16637:2016 Radiological protection – Monitoring and internal dosimetry for staff members exposed to medical radionuclides as unsealed sources

CDN $306.00

SKU: f072af6a223b Category:

Description

ISO 16637:2016 specifies the minimum requirements for the design of professional programmes to monitor workers exposed to the risk of internal contamination via inhalation by the use of radionuclides as unsealed sources in nuclear medicine imaging and therapy departments. It establishes principles for the development of compatible goals and requirements for monitoring programmes and, when adequate, dose assessment. It presents procedures and assumptions for the risk analysis, for the monitoring programmes, and for the standardized interpretation of monitoring data.

ISO 16637:2016 addresses the following items:

a) purposes of monitoring and monitoring programmes;

b) description of the different categories of monitoring programmes;

c) quantitative criteria for conducting monitoring programmes;

d) suitable methods for monitoring and criteria for their selection;

e) information that has to be collected for the design of a monitoring programme;

f) general requirements for monitoring programmes (e.g. detection limits, tolerated uncertainties);

g) frequencies of measurements;

h) procedures for dose assessment based on reference levels for routine and special monitoring programmes;

i) assumptions for the selection of dose-critical parameter values;

j) criteria for determining the significance of individual monitoring results;

k) interpretation of workplace monitoring results;

l) uncertainties arising from dose assessments and interpretation of bioassays data;

m) reporting/documentation;

n) quality assurance.

ISO 16637:2016 does not address the following:

– monitoring and internal dosimetry for the workers exposed to laboratory use of radionuclides such as radioimmunoassay techniques;

– monitoring and internal dosimetry for the workers involved in the operation, maintenance, and servicing of PET cyclotrons;

– detailed descriptions of measuring methods and techniques;

– dosimetry for litigation cases;

– modelling for the improvement of internal dosimetry;

– the potential influence of medical treatment of the internal contamination;

– the investigation of the causes or implications of an exposure;

– dosimetry for ingestion exposures and for contaminated wounds.

Edition

1

Published Date

2016-02-18

Status

PUBLISHED

Pages

28

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 16637:2016 specifies the minimum requirements for the design of professional programmes to monitor workers exposed to the risk of internal contamination via inhalation by the use of radionuclides as unsealed sources in nuclear medicine imaging and therapy departments. It establishes principles for the development of compatible goals and requirements for monitoring programmes and, when adequate, dose assessment. It presents procedures and assumptions for the risk analysis, for the monitoring programmes, and for the standardized interpretation of monitoring data.

ISO 16637:2016 addresses the following items:

a) purposes of monitoring and monitoring programmes;

b) description of the different categories of monitoring programmes;

c) quantitative criteria for conducting monitoring programmes;

d) suitable methods for monitoring and criteria for their selection;

e) information that has to be collected for the design of a monitoring programme;

f) general requirements for monitoring programmes (e.g. detection limits, tolerated uncertainties);

g) frequencies of measurements;

h) procedures for dose assessment based on reference levels for routine and special monitoring programmes;

i) assumptions for the selection of dose-critical parameter values;

j) criteria for determining the significance of individual monitoring results;

k) interpretation of workplace monitoring results;

l) uncertainties arising from dose assessments and interpretation of bioassays data;

m) reporting/documentation;

n) quality assurance.

ISO 16637:2016 does not address the following:

- monitoring and internal dosimetry for the workers exposed to laboratory use of radionuclides such as radioimmunoassay techniques;

- monitoring and internal dosimetry for the workers involved in the operation, maintenance, and servicing of PET cyclotrons;

- detailed descriptions of measuring methods and techniques;

- dosimetry for litigation cases;

- modelling for the improvement of internal dosimetry;

- the potential influence of medical treatment of the internal contamination;

- the investigation of the causes or implications of an exposure;

- dosimetry for ingestion exposures and for contaminated wounds.

Previous Editions

Can’t find what you are looking for?

Please contact us at: