ISO 16645:2016
ISO 16645:2016 Radiological protection – Medical electron accelerators – Requirements and recommendations for shielding design and evaluation
CDN $351.00
Description
ISO 16645:2016 is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.
The cyclotrons and the synchrotrons used for hadrontherapy are not considered.
The radiation protection requirements and recommendations given in ISO 16645:2016 cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).
Edition
1
Published Date
2016-09-19
Status
PUBLISHED
Pages
76
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 16645:2016 is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.
The cyclotrons and the synchrotrons used for hadrontherapy are not considered.
The radiation protection requirements and recommendations given in ISO 16645:2016 cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 9698:2019 Water quality – Tritium – Test method using liquid scintillation counting
CDN $233.00 Add to cart -

ISO 12749:2018 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 5: Nuclear reactors
CDN $76.00 Add to cart -

ISO 20899:2018 Water quality – Plutonium and neptunium – Test method using ICP-MS
CDN $173.00 Add to cart -

ISO 6962:2004 Nuclear energy – Standard method for testing the long-term alpha irradiation stability of matrices for solidification of high-level radioactive waste
CDN $115.00 Add to cart