ISO 16645:2016
ISO 16645:2016 Radiological protection – Medical electron accelerators – Requirements and recommendations for shielding design and evaluation
CDN $391.00
Description
ISO 16645:2016 is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.
The cyclotrons and the synchrotrons used for hadrontherapy are not considered.
The radiation protection requirements and recommendations given in ISO 16645:2016 cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).
Edition
1
Published Date
2016-09-19
Status
PUBLISHED
Pages
76
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 16645:2016 is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.
The cyclotrons and the synchrotrons used for hadrontherapy are not considered.
The radiation protection requirements and recommendations given in ISO 16645:2016 cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22017:2020 Water quality – Guidance for rapid radioactivity measurements in nuclear or radiological emergency situation
CDN $259.00 Add to cart -

ISO 20553:2025 Radiation protection – Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material
CDN $305.00 Add to cart -

ISO 361:1975 Basic ionizing radiation symbol
CDN $85.00 Add to cart -

ISO 22127:2019 Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy
CDN $192.00 Add to cart