Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 5C3: Calculating Performance Properties of Pipe Used as Casing or Tubing

$

422

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services

$

502

BUY NOW

Placeholder headline

This is just a placeholder headline

Technical Report API TBD-10: Chapter 10 Surface and Interfacial Tension

$

176

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-44-2026: Steel Pipeline Flanges

$

450

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 591: Process Valve Qualification Procedure

$

226

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices: Addendum 1

$

0

BUY NOW

ISO 16775:2021

ISO 16775:2021 Packaging for terminally sterilized medical devices – Guidance on the application of ISO 11607-1 and ISO 11607-2

CDN $390.00

SKU: 79f858acac93 Category:

Description

This document provides guidance for the application of the requirements contained in ISO 11607-1 and ISO 11607-2. It does not add to, or otherwise change, the requirements of ISO 11607-1 and ISO 11607-2. This is an informative document, not normative. It does not include requirements to be used as basis of regulatory inspection or certification assessment activities.

The guidance can be used to better understand the requirements of ISO 11607-1 and ISO 11607-2 and illustrates the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required that this document be used to demonstrate conformity with them.

Guidance is given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given.

This document provides information for both healthcare facilities and the medical devices industry for terminally sterilized medical devices.

This document does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a “sterile field” or transport of contaminated items, other regulatory standards will apply.

Edition

2

Published Date

2021-11-05

Status

PUBLISHED

Pages

143

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document provides guidance for the application of the requirements contained in ISO 11607-1 and ISO 11607-2. It does not add to, or otherwise change, the requirements of ISO 11607-1 and ISO 11607-2. This is an informative document, not normative. It does not include requirements to be used as basis of regulatory inspection or certification assessment activities.

The guidance can be used to better understand the requirements of ISO 11607-1 and ISO 11607-2 and illustrates the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required that this document be used to demonstrate conformity with them.

Guidance is given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given.

This document provides information for both healthcare facilities and the medical devices industry for terminally sterilized medical devices.

This document does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a “sterile field” or transport of contaminated items, other regulatory standards will apply.