
ISO 16793:2018
ISO 16793:2018 Nuclear fuel technology – Guidelines for ceramographic preparation of UO2 sintered pellets for microstructure examination
CDN $129.00
Description
This document describes the ceramographic preparation of uranium dioxide (UO2) sintered pellets for qualitative and quantitative microstructure examinations.
These examinations can be carried out before and after thermal or chemical etching.
They enable
– observations of fissures, inter- or intra-granular pores and inclusions, and
– measurement of pore and grain size and measurement of pore and grain size distributions.
The measurement of average grain size can be carried out using a classical counting method as described in ISO 2624 or ASTM E112[3], i.e. intercept procedure, comparison with standard grids or reference photographs.
The measurement of pore-size distributions is usually carried out by an automatic image analyser. If the grain-size distributions are also measured with an image analyser, it is recommended that thermal etching be used to reveal the grain structure uniformly throughout the whole sample.
Edition
2
Published Date
2018-07-31
Status
PUBLISHED
Pages
8
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document describes the ceramographic preparation of uranium dioxide (UO2) sintered pellets for qualitative and quantitative microstructure examinations.
These examinations can be carried out before and after thermal or chemical etching.
They enable
- observations of fissures, inter- or intra-granular pores and inclusions, and
- measurement of pore and grain size and measurement of pore and grain size distributions.
The measurement of average grain size can be carried out using a classical counting method as described in ISO 2624 or ASTM E112[3], i.e. intercept procedure, comparison with standard grids or reference photographs.
The measurement of pore-size distributions is usually carried out by an automatic image analyser. If the grain-size distributions are also measured with an image analyser, it is recommended that thermal etching be used to reveal the grain structure uniformly throughout the whole sample.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 11483:2005 Nuclear fuel technology – Preparation of plutonium sources and determination of 238Pu/239Pu isotope ratio by alpha spectrometry
CDN $191.00 Add to cart -

ISO 6863:2024 Nuclear fuel technology – Preparation of spikes for isotope dilution mass spectrometry (IDMS)
CDN $192.00 Add to cart -

ISO 13464:1998 Simultaneous determination of uranium and plutonium in dissolver solutions from reprocessing plants – Combined method using K-absorption edge and X-ray fluorescence spectrometry
CDN $192.00 Add to cart -

ISO 21391:2019 Nuclear criticality safety – Geometrical dimensions for subcriticality control – Equipment and layout
CDN $192.00 Add to cart







