Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 17091:2013

ISO 17091:2013 Workplace air – Determination of lithium hydroxide, sodium hydroxide, potassium hydroxide and calcium dihydroxide – Method by measurement of corresponding cations by suppressed ion chromatography

CDN $273.00

Description

ISO 17091:2013 specifies a method for the determination of the time-weighted average mass concentration of lithium hydroxide (LiOH), sodium hydroxide (NaOH), potassium hydroxide (KOH), and calcium dihydroxide [Ca(OH)2] in workplace air by collection of the particulate hydroxides on a filter and analysis of the corresponding cations using ion chromatography.

For aerosol sampling, the method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling.

The method is applicable to the determination of masses of 0,005 mg to at least 2,5 mg of lithium per sample and 0,01 mg to at least 5 mg of sodium, potassium, and calcium per sample.

The concentration range of particulate LiOH, NaOH, KOH, and Ca(OH)2 in air for which the measuring procedure is applicable is determined by the sampling method selected by the user. For a 1 m3 air sample, the working range is approximately 0,002 mg m‚àí3 to at least 20 mg m‚àí3 for all four hydroxides. For a 30 l air sample, the lower limit of the working range is approximately 0,1 mg m‚àí3 for all four hydroxides.

The procedure does not allow differentiation between the hydroxides and their corresponding salts if both are present in the air. If the cations are present alone in the form of hydroxides, the method is specific for these basic compounds. In other circumstances, the results obtained represent the highest concentration of the hydroxides that could be present in the sampled air.

Edition

1

Published Date

2013-09-11

Status

PUBLISHED

Pages

28

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 17091:2013 specifies a method for the determination of the time-weighted average mass concentration of lithium hydroxide (LiOH), sodium hydroxide (NaOH), potassium hydroxide (KOH), and calcium dihydroxide [Ca(OH)2] in workplace air by collection of the particulate hydroxides on a filter and analysis of the corresponding cations using ion chromatography.

For aerosol sampling, the method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling.

The method is applicable to the determination of masses of 0,005 mg to at least 2,5 mg of lithium per sample and 0,01 mg to at least 5 mg of sodium, potassium, and calcium per sample.

The concentration range of particulate LiOH, NaOH, KOH, and Ca(OH)2 in air for which the measuring procedure is applicable is determined by the sampling method selected by the user. For a 1 m3 air sample, the working range is approximately 0,002 mg m‚àí3 to at least 20 mg m‚àí3 for all four hydroxides. For a 30 l air sample, the lower limit of the working range is approximately 0,1 mg m‚àí3 for all four hydroxides.

The procedure does not allow differentiation between the hydroxides and their corresponding salts if both are present in the air. If the cations are present alone in the form of hydroxides, the method is specific for these basic compounds. In other circumstances, the results obtained represent the highest concentration of the hydroxides that could be present in the sampled air.