Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 17123:2001

ISO 17123:2001 Optics and optical instruments – Field procedures for testing geodetic and surveying instruments – Part 2: Levels

CDN $186.00

SKU: 20e1f3b2d251 Categories: ,

Description

This part of ISO 17123 specifies field procedures to be adopted when determining and evaluating the precision of

levels (spirit levels, compensator levels, digital levels) and their ancillary equipment when used in building and

surveying measurements. Primarily, these tests are intended to be field verifications of the suitability of a particular

instrument for the immediate task at hand and to satisfy the requirements of other standards. They are not proposed

as tests for acceptance or performance evaluations that are more comprehensive in nature.

This International Standard can be thought of as one of the first steps in the process of evaluating the uncertainty of

a measurement (more specifically a measurand). The uncertainty of a result of a measurement is dependent on a

number of factors. These include among others: repeatability, reproducibility (between day repeatability) and a

thorough assessment of all possible error sources, as prescribed by the ISO Guide to the expression of uncertainty

in measurement (GUM).

These field procedures have been developed specifically for in situ applications without the need for special ancillary

equipment and are purposely designed to minimize atmospheric influences.

Edition

1

Published Date

2001-12-06

Status

PUBLISHED

Pages

14

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This part of ISO 17123 specifies field procedures to be adopted when determining and evaluating the precision of

levels (spirit levels, compensator levels, digital levels) and their ancillary equipment when used in building and

surveying measurements. Primarily, these tests are intended to be field verifications of the suitability of a particular

instrument for the immediate task at hand and to satisfy the requirements of other standards. They are not proposed

as tests for acceptance or performance evaluations that are more comprehensive in nature.

This International Standard can be thought of as one of the first steps in the process of evaluating the uncertainty of

a measurement (more specifically a measurand). The uncertainty of a result of a measurement is dependent on a

number of factors. These include among others: repeatability, reproducibility (between day repeatability) and a

thorough assessment of all possible error sources, as prescribed by the ISO Guide to the expression of uncertainty

in measurement (GUM).

These field procedures have been developed specifically for in situ applications without the need for special ancillary

equipment and are purposely designed to minimize atmospheric influences.