
ISO 17123:2001
ISO 17123:2001 Optics and optical instruments – Field procedures for testing geodetic and surveying instruments – Part 3: Theodolites
CDN $263.00
Description
This part of ISO 17123 specifies field procedures to be adopted when determining and evaluating the precision (repeatability)
of theodolites and their ancillary equipment when used in building and surveying measurements. Primarily,
these tests are intended to be field verifications of the suitability of a particular instrument for the immediate task
at hand and to satisfy the requirements of other standards. They are not proposed as tests for acceptance or performance
evaluations that are more comprehensive in nature.
This part of ISO 17123 can be thought of as one of the first steps in the process of evaluating the uncertainty of a
measurement (more specifically a measurand). The uncertainty of a result of a measurement is dependent on a
number of factors. These include among others: repeatability (precision), reproducibility (between day repeatability),
traceability (an unbroken chain to national standards) and a thorough assessment of all possible error sources, as
prescribed by the ISO Guide to the expression of uncertainty in measurement (GUM).
These field procedures have been developed specifically for in situ applications without the need for special ancillary
equipment and are purposefully designed to minimize atmospheric influences.
Edition
1
Published Date
2001-12-13
Status
PUBLISHED
Pages
21
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This part of ISO 17123 specifies field procedures to be adopted when determining and evaluating the precision (repeatability)
of theodolites and their ancillary equipment when used in building and surveying measurements. Primarily,
these tests are intended to be field verifications of the suitability of a particular instrument for the immediate task
at hand and to satisfy the requirements of other standards. They are not proposed as tests for acceptance or performance
evaluations that are more comprehensive in nature.
This part of ISO 17123 can be thought of as one of the first steps in the process of evaluating the uncertainty of a
measurement (more specifically a measurand). The uncertainty of a result of a measurement is dependent on a
number of factors. These include among others: repeatability (precision), reproducibility (between day repeatability),
traceability (an unbroken chain to national standards) and a thorough assessment of all possible error sources, as
prescribed by the ISO Guide to the expression of uncertainty in measurement (GUM).
These field procedures have been developed specifically for in situ applications without the need for special ancillary
equipment and are purposefully designed to minimize atmospheric influences.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 80000:2025 Quantities and units – Part 13: Information science and technology
CDN $224.00 Add to cart -

ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
CDN $352.00 Add to cart -

ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
CDN $263.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $86.00 Add to cart







