Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 17191:2004

ISO 17191:2004 Urine-absorbing aids for incontinence – Measurement of airborne respirable polyacrylate superabsorbent materials – Determination of dust in collection cassettes by sodium atomic absorption spectrometry

CDN $124.00

Description

ISO 17191:2004 specifies a method for the determination of polyacrylate (PA) superabsorbent powders in airborne dust by measurement of sodium (Na) by atomic absorption spectrometry (AAS). PA dust samples are collected in polystyrene acrylonitrile air-monitoring cassettes with polytetrafluoroethylene filters and porous plastic backing pads.

This method is applicable to the determination of collected superabsorbent powder in the range between 0,2 micrograms and 60 micrograms (limit of detection near 0,2 micrograms) of superabsorbent powders.

Edition

1

Published Date

2004-01-23

Status

PUBLISHED

Pages

9

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 17191:2004 specifies a method for the determination of polyacrylate (PA) superabsorbent powders in airborne dust by measurement of sodium (Na) by atomic absorption spectrometry (AAS). PA dust samples are collected in polystyrene acrylonitrile air-monitoring cassettes with polytetrafluoroethylene filters and porous plastic backing pads.

This method is applicable to the determination of collected superabsorbent powder in the range between 0,2 micrograms and 60 micrograms (limit of detection near 0,2 micrograms) of superabsorbent powders.

Previous Editions

Can’t find what you are looking for?

Please contact us at: