Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 17293:2014

ISO 17293:2014 Surface active agents – Determination of chloroacetic acid (chloroacetate) in surfactants – Part 2: Ionic chromatographic method

CDN $86.00

SKU: 3b7e079e9222 Category:

Description

ISO 17293-2:2014 specifies a method for the determination of monochloroacetic acid (monochloroacetate) and dichloroacetic acid (dichloroacetate) in surfactants by ion chromatographic method.

The method applies for anionic surfactants such as alkyl (phenyl) ethoxylated carboxylate (AEC) or amphoteric surfactants such as alkyl imidazoline carboxylate, alkyl dimethyl betaine, and fatty acetyl propyl dimethyl betaine.

The limit of detection (LOD) is ≤0,01 µg/ml for monochloroacetic acid and ≤0,05 µg/ml for dichloroacetic acid; and the limit of quantification (LOQ) is ≤0,1 µg/ml for each standard (using a standard solution).

The LOD, at 1 g of sample weight, is ‚â§1 mg/kg for monochloroacetic acid and ‚â§5 mg/kg for dichloroacetic acid; and the LOQ is ‚â§10 mg/kg for each acid.

Edition

1

Published Date

2014-03-19

Status

PUBLISHED

Pages

6

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 17293-2:2014 specifies a method for the determination of monochloroacetic acid (monochloroacetate) and dichloroacetic acid (dichloroacetate) in surfactants by ion chromatographic method.

The method applies for anionic surfactants such as alkyl (phenyl) ethoxylated carboxylate (AEC) or amphoteric surfactants such as alkyl imidazoline carboxylate, alkyl dimethyl betaine, and fatty acetyl propyl dimethyl betaine.

The limit of detection (LOD) is ≤0,01 µg/ml for monochloroacetic acid and ≤0,05 µg/ml for dichloroacetic acid; and the limit of quantification (LOQ) is ≤0,1 µg/ml for each standard (using a standard solution).

The LOD, at 1 g of sample weight, is ‚â§1 mg/kg for monochloroacetic acid and ‚â§5 mg/kg for dichloroacetic acid; and the LOQ is ‚â§10 mg/kg for each acid.

Previous Editions

Can’t find what you are looking for?

Please contact us at: