Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 17858:2007

ISO 17858:2007 Water quality – Determination of dioxin-like polychlorinated biphenyls – Method using gas chromatography/mass spectrometry

CDN $351.00

SKU: b6c3b4589ba7 Category:

Description

ISO 17858:2007 specifies a method for the determination of dioxin-like tetra- to hepta-chlorinated biphenyls (PCBs) in waters and wastewaters (containing less than 1 % suspended solids) using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The minimum levels at which the dioxin-like PCBs can typically be determined with no interferences present are specified. This method is “performance based”. The analyst is permitted to modify the method to overcome interferences or lower the cost of measurements, provided that all performance criteria in this method are met. The requirements for establishing method equivalency are given.

Edition

1

Published Date

2007-02-12

Status

PUBLISHED

Pages

54

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 17858:2007 specifies a method for the determination of dioxin-like tetra- to hepta-chlorinated biphenyls (PCBs) in waters and wastewaters (containing less than 1 % suspended solids) using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The minimum levels at which the dioxin-like PCBs can typically be determined with no interferences present are specified. This method is "performance based". The analyst is permitted to modify the method to overcome interferences or lower the cost of measurements, provided that all performance criteria in this method are met. The requirements for establishing method equivalency are given.

Previous Editions

Can’t find what you are looking for?

Please contact us at: