ISO 17951:2016
ISO 17951:2016 Water quality – Determination of fluoride using flow analysis (FIA and CFA) – Part 1: Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation
CDN $131.00
Description
ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described:
– working range I: 0,1 mg/l to 1 mg/l;
– working range II: 1 mg/l to 10 mg/l.
The specification of the calibration solutions are to be adapted accordingly.
Edition
1
Published Date
2016-06-17
Status
PUBLISHED
Pages
12
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. It is not recommended for drinking waters where a distillation step is not required. In ISO/TS 17951-1:2016, two working ranges are described:
- working range I: 0,1 mg/l to 1 mg/l;
- working range II: 1 mg/l to 10 mg/l.
The specification of the calibration solutions are to be adapted accordingly.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16265:2009 Water quality – Determination of the methylene blue active substances (MBAS) index – Method using continuous flow analysis (CFA)
CDN $131.00 Add to cart -

ISO 21793:2020 Water quality – Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb), dissolved bound nitrogen (DNb), total bound phosphorus (TPb) and dissolved bound phosphorus (DPb) after wet chemical catalysed ozone hydroxyl radical oxidation (COHR)
CDN $310.00 Add to cart -

ISO 22478:2006 Water quality – Determination of certain explosives and related compounds – Method using high-performance liquid chromatography (HPLC) with UV detection
CDN $263.00 Add to cart -

ISO 15680:2003 Water quality – Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
CDN $310.00 Add to cart