ISO 18213:2007
ISO 18213:2007 Nuclear fuel technology – Tank calibration and volume determination for nuclear materials accountancy – Part 2: Data standardization for tank calibration
CDN $186.00
Description
ISO 18213-2:2007 presents procedures for standardizing a set of calibration data to a fixed set of reference conditions so as to minimize the effect of variations in ambient conditions that occur during the measurement process. The procedures presented herein apply generally to measurements of liquid height and volume obtained for the purpose of calibrating a tank (i.e., calibrating a tank’s measurement system). When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped with bubbler probe systems for measuring liquid content.
The standardization algorithms presented in ISO 18213-2:2007 can be profitably applied when only estimates of ambient conditions, such as temperature, are available. However, the most reliable results are obtained when relevant ambient conditions are measured for each measurement of volume and liquid height in a set of calibration data.
Edition
1
Published Date
2007-10-31
Status
PUBLISHED
Pages
15
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 18213-2:2007 presents procedures for standardizing a set of calibration data to a fixed set of reference conditions so as to minimize the effect of variations in ambient conditions that occur during the measurement process. The procedures presented herein apply generally to measurements of liquid height and volume obtained for the purpose of calibrating a tank (i.e., calibrating a tank's measurement system). When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped with bubbler probe systems for measuring liquid content.
The standardization algorithms presented in ISO 18213-2:2007 can be profitably applied when only estimates of ambient conditions, such as temperature, are available. However, the most reliable results are obtained when relevant ambient conditions are measured for each measurement of volume and liquid height in a set of calibration data.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 13464:1998 Simultaneous determination of uranium and plutonium in dissolver solutions from reprocessing plants – Combined method using K-absorption edge and X-ray fluorescence spectrometry
CDN $186.00 Add to cart -

ISO 16795:2024 Nuclear energy – Determination of Gd2O3 content in pellets containing uranium oxide by X-ray fluorescence spectrometry
CDN $124.00 Add to cart -

ISO 24459:2021 Determination of uranium content in samples coming from the nuclear fuel cycle by L-absorption edge spectrometry
CDN $186.00 Add to cart -

ISO 12807:2018 Safe transport of radioactive materials – Leakage testing on packages
CDN $422.00 Add to cart