
ISO 18250:2018
ISO 18250:2018 Medical devices – Connectors for reservoir delivery systems for healthcare applications – Part 7: Connectors for intravascular infusion
CDN $310.00
Description
This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.
This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.
EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:
– Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;
– Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;
– Syringes and syringe IV sets utilizing Luer connectors.
The following connectors are excluded from the scope of this document:
– Stoppers for bottles as specified in ISO 8536-2;
– Compounding/admixture ports on IV reservoirs and intended mating devices.
EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).
– The fill ports of non-powered (i.e. elastomeric) pumps.
NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.
NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.
Edition
1
Published Date
2018-12-17
Status
PUBLISHED
Pages
34
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.
This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.
EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:
- Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;
- Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;
- Syringes and syringe IV sets utilizing Luer connectors.
The following connectors are excluded from the scope of this document:
- Stoppers for bottles as specified in ISO 8536-2;
- Compounding/admixture ports on IV reservoirs and intended mating devices.
EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).
- The fill ports of non-powered (i.e. elastomeric) pumps.
NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.
NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 10555:2023 Intravascular catheters – Sterile and single-use catheters – Part 7: Peripherally inserted central catheters
CDN $86.00 Add to cart -

ISO 10555:2024 Intravascular catheters – Sterile and single-use catheters – Part 8: Catheters for extracorporeal blood treatment
CDN $131.00 Add to cart -

ISO 23908:2024 Sharps injury protection – Sharps protection mechanisms for single-use needles, introducers for catheters and needles used for blood testing, monitoring, sampling and medical substance administration – Requirements and test methods
CDN $195.00 Add to cart -

ISO 18250:2018 Medical devices – Connectors for reservoir delivery systems for healthcare applications – Part 8: Citrate-based anticoagulant solution for apheresis applications
CDN $263.00 Add to cart







