Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 18549:2009

ISO 18549:2009 Metallic powders – Determination of apparent density and flow rate at elevated temperatures – Part 2: Determination of flow rate at elevated temperatures

CDN $76.00

Description

ISO 18549-2:2009 describes two methods for the determination of the time (flow rate) it takes for a given quantity of a heated powder mix, based on iron or steel powders and to be used for warm compaction, to pass through a funnel with a given orifice diameter.

Method A uses a funnel with an orifice of 2,5 mm and a test portion of 50 g and is, to a large extent, based on the method standardized in ISO 4490:2008. The method can only be used for powder mixes that flow freely through the 2,5 mm orifice in the heated condition.

Method B uses a funnel with an orifice of 5 mm and a test portion with a size of 150 g.

Both methods cover a testing temperature range of 60 °C to 180 °C and either of them can be selected after agreement between the parties involved.

Edition

1

Published Date

2009-04-03

Status

PUBLISHED

Pages

5

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 18549-2:2009 describes two methods for the determination of the time (flow rate) it takes for a given quantity of a heated powder mix, based on iron or steel powders and to be used for warm compaction, to pass through a funnel with a given orifice diameter.

Method A uses a funnel with an orifice of 2,5 mm and a test portion of 50 g and is, to a large extent, based on the method standardized in ISO 4490:2008. The method can only be used for powder mixes that flow freely through the 2,5 mm orifice in the heated condition.

Method B uses a funnel with an orifice of 5 mm and a test portion with a size of 150 g.

Both methods cover a testing temperature range of 60 °C to 180 °C and either of them can be selected after agreement between the parties involved.