Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 18754:2020

ISO 18754:2020 Fine ceramics (advanced ceramics, advanced technical ceramics) – Determination of density and apparent porosity

CDN $131.00

SKU: 048bc8f46f94 Categories: ,

Description

This document specifies methods for the determination of the apparent solid density, bulk density, apparent porosity and geometric bulk density of fine ceramics, including all ceramic matrix composites.

Two methods are described and are designated as Methods A and B, as follows:

– Method A: Determination of bulk density, apparent solid density and apparent porosity by liquid displacement (Archimedes’ method).

NOTE 1 This method is not appropriate for the determination of an apparent porosity greater than 10 %. For materials with higher porosity, the accuracy of the measurement might not be satisfactory. This method might also not give a satisfactory open porosity result if it is less than 0,5 %.

NOTE 2 This method is also not suitable for materials which are known to have an average pore size of greater than 600 µm.

– Method B: Determination of bulk density only, by measurement of geometric dimensions and mass.

Edition

3

Published Date

2020-04-30

Status

PUBLISHED

Pages

10

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies methods for the determination of the apparent solid density, bulk density, apparent porosity and geometric bulk density of fine ceramics, including all ceramic matrix composites.

Two methods are described and are designated as Methods A and B, as follows:

- Method A: Determination of bulk density, apparent solid density and apparent porosity by liquid displacement (Archimedes' method).

NOTE 1 This method is not appropriate for the determination of an apparent porosity greater than 10 %. For materials with higher porosity, the accuracy of the measurement might not be satisfactory. This method might also not give a satisfactory open porosity result if it is less than 0,5 %.

NOTE 2 This method is also not suitable for materials which are known to have an average pore size of greater than 600 µm.

- Method B: Determination of bulk density only, by measurement of geometric dimensions and mass.

Previous Editions

Can’t find what you are looking for?

Please contact us at: