Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 19040:2018

ISO 19040:2018 Water quality – Determination of the estrogenic potential of water and waste water – Part 2: Yeast estrogen screen (A-YES, Arxula adeninivorans)

CDN $379.00

SKU: bf0950c4c9ea Category:

Description

This document specifies a method for the determination of the estrogenic potential of water and waste water by means of a reporter gene assay with a genetically modified yeast strain Arxula adeninivorans. This reporter gene assay is based on the activation of the human estrogen receptor alpha.

Arxula adeninivorans is a highly robust and salt- and temperature-tolerant test organism and is especially suitable for the analysis of samples with high salinity (conductivity up to 70 mS/cm). The test organism can be cultivated in medium with sodium chloride content up to 20 %.

This method is applicable to:

– fresh water;

– waste water;

– sea water;

– brackish water;

– aqueous extracts and leachates;

– eluates of sediments (fresh water);

– pore water;

– aqueous solutions of single substances or of chemical mixtures;

– drinking water.

The limit of quantification (LOQ) of this method for the direct analysis of water samples is between 1,5 ng/l and 3 ng/l 17β-estradiol equivalents (EEQ). The upper threshold of the dynamic range for this test is between 25 ng/l and 40 ng/l 17β-estradiol equivalents (EEQ). Samples showing estrogenic potencies above this threshold have to be diluted for a valid quantification. Extraction and pre-concentration of water samples can prove necessary, if their estrogenic potential is below the given LOQ.

An international interlaboratory trial for the validation of this document has been carried out. The results are summarized in Annex F.

NOTE Extraction and pre-concentration of water samples can prove necessary.

Edition

1

Published Date

2018-08-07

Status

PUBLISHED

Pages

55

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for the determination of the estrogenic potential of water and waste water by means of a reporter gene assay with a genetically modified yeast strain Arxula adeninivorans. This reporter gene assay is based on the activation of the human estrogen receptor alpha.

Arxula adeninivorans is a highly robust and salt- and temperature-tolerant test organism and is especially suitable for the analysis of samples with high salinity (conductivity up to 70 mS/cm). The test organism can be cultivated in medium with sodium chloride content up to 20 %.

This method is applicable to:

- fresh water;

- waste water;

- sea water;

- brackish water;

- aqueous extracts and leachates;

- eluates of sediments (fresh water);

- pore water;

- aqueous solutions of single substances or of chemical mixtures;

- drinking water.

The limit of quantification (LOQ) of this method for the direct analysis of water samples is between 1,5 ng/l and 3 ng/l 17β-estradiol equivalents (EEQ). The upper threshold of the dynamic range for this test is between 25 ng/l and 40 ng/l 17β-estradiol equivalents (EEQ). Samples showing estrogenic potencies above this threshold have to be diluted for a valid quantification. Extraction and pre-concentration of water samples can prove necessary, if their estrogenic potential is below the given LOQ.

An international interlaboratory trial for the validation of this document has been carried out. The results are summarized in Annex F.

NOTE Extraction and pre-concentration of water samples can prove necessary.