Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 1996:2022

ISO 1996:2022 Acoustics – Description, measurement and assessment of environmental noise – Part 3: Objective method for the measurement of prominence of impulsive sounds and for adjustment of L Aeq

CDN $115.00

Description

This method objectively categorises sources by determination of the prominence of impulsive sound, with the aim of correlating to community response. This method for measuring the prominence of impulsive sounds is intended for sources not identified as gunfire or high-energy impulsive sound. It typically produces adjustments in the range 0,0 dB to 9,0 dB. These adjustments are intended to be used to categorise the sources as either regular impulsive or highly impulsive sound sources and apply the penalty indicated in ISO 1996-1. However, the adjustments may be applied directly, as is done in NT ACOU 112[2], and BS 4142[3]. ISO 1996-2 provides additional guidance for performing these measurements.

The method is intended for use on sources with impulsive characteristics that are not already categorised in ISO 1996-1. A non-exhaustive list of examples includes compressed air release, scrap handling, goods delivery, fork lifts with rattling forks, skateboard ramps, industrial shearing, gas discharges, percussive tools in demolition, powered riveting, etc.

The method is not intended for use on sounds from firearms. Although the measurements of prominence may give relevant results, research has shown the response to these sources is influenced by factors outside of the scope of this document. In addition, the method is not intended to use for high-energy impulsive sound sources as specified in ISO 1996-1.

NOTE      This method is not intended for occupational hearing loss, which is outside the scope of this document.

See Annex A for recommended additional research.

Edition

1

Published Date

2022-07-06

Status

PUBLISHED

Pages

10

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This method objectively categorises sources by determination of the prominence of impulsive sound, with the aim of correlating to community response. This method for measuring the prominence of impulsive sounds is intended for sources not identified as gunfire or high-energy impulsive sound. It typically produces adjustments in the range 0,0 dB to 9,0 dB. These adjustments are intended to be used to categorise the sources as either regular impulsive or highly impulsive sound sources and apply the penalty indicated in ISO 1996-1. However, the adjustments may be applied directly, as is done in NT ACOU 112[2], and BS 4142[3]. ISO 1996-2 provides additional guidance for performing these measurements.

The method is intended for use on sources with impulsive characteristics that are not already categorised in ISO 1996-1. A non-exhaustive list of examples includes compressed air release, scrap handling, goods delivery, fork lifts with rattling forks, skateboard ramps, industrial shearing, gas discharges, percussive tools in demolition, powered riveting, etc.

The method is not intended for use on sounds from firearms. Although the measurements of prominence may give relevant results, research has shown the response to these sources is influenced by factors outside of the scope of this document. In addition, the method is not intended to use for high-energy impulsive sound sources as specified in ISO 1996-1.

NOTE      This method is not intended for occupational hearing loss, which is outside the scope of this document.

See Annex A for recommended additional research.

Previous Editions