
ISO 20552:2007
ISO 20552:2007 Workplace air – Determination of mercury vapour – Method using gold-amalgam collection and analysis by atomic absorption spectrometry or atomic fluorescence spectrometry
CDN $259.00
Description
ISO 20552:2007 specifies a procedure for determination of the mass concentration of mercury vapour in workplace air using a method of gold-amalgam collection with analysis by either cold vapour atomic absorption spectrometry (CVAAS) or cold vapour atomic fluorescence spectrometry (CVAFS). The procedure specifies a number of sampling methods for different applications.
The procedure is suitable for making short-term measurements (e.g. 15 min) when sampling at a flow rate of between 100 ml per min and 1 000 ml per min. For assessment of long-term exposure, such as 8 h, this procedure can be used with sampling flow rate of 100 ml per min in workplaces where the concentration of mercury vapour is expected to be lower than 20 micrograms per cubic metre. If the expected concentration of mercury vapour is higher than 20 micrograms per cubic metre, it is necessary to use the procedure prescribed in ISO 17733.
ISO 20552:2007 is unsuitable for making measurements of mercury vapour in air when chlorine is present in the atmosphere, e.g. in chloralkali works. Gaseous organo-mercury compounds can cause a positive interference.
Edition
1
Published Date
2007-02-06
Status
PUBLISHED
Pages
24
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 20552:2007 specifies a procedure for determination of the mass concentration of mercury vapour in workplace air using a method of gold-amalgam collection with analysis by either cold vapour atomic absorption spectrometry (CVAAS) or cold vapour atomic fluorescence spectrometry (CVAFS). The procedure specifies a number of sampling methods for different applications.
The procedure is suitable for making short-term measurements (e.g. 15 min) when sampling at a flow rate of between 100 ml per min and 1 000 ml per min. For assessment of long-term exposure, such as 8 h, this procedure can be used with sampling flow rate of 100 ml per min in workplaces where the concentration of mercury vapour is expected to be lower than 20 micrograms per cubic metre. If the expected concentration of mercury vapour is higher than 20 micrograms per cubic metre, it is necessary to use the procedure prescribed in ISO 17733.
ISO 20552:2007 is unsuitable for making measurements of mercury vapour in air when chlorine is present in the atmosphere, e.g. in chloralkali works. Gaseous organo-mercury compounds can cause a positive interference.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 2382:2015 Information technology – Vocabulary
CDN $0.00 Add to cart -

ISO 17097:2024 3-D human body scan data – Methods for the processing of human body scan data
CDN $192.00 Add to cart -

ISO 15708:2024 Non-destructive testing – Radiation methods for computed tomography – Part 1: Vocabulary
CDN $85.00 Add to cart -

ISO 55000:2024 Asset management – Vocabulary, overview and principles
CDN $259.00 Add to cart







