ISO 20596:2018
ISO 20596:2018 Water quality – Determination of cyclic volatile methylsiloxanes in water – Part 1: Method using purge and trap with gas chromatography-mass spectrometry (GC-MS)
CDN $251.00
Description
This document specifies a method for the quantitative determination of selected cyclic volatile methylsiloxanes (cVMS) in non-filtered water samples by purge and trap extraction with isotope dilution gas chromatography-mass spectrometry (GC-MS).
This method is applicable to the determination of individual cVMS, including:
– octamethylcyclotetrasiloxane (D4);
– decamethylcyclopentasiloxane (D5);
– dodecamethylcyclohexasiloxane (D6);
in surface water, ground water, and wastewater. It can be applied to samples within the concentration range of 0,01 µg/l to 1 µg/l of each of the target compounds. Depending on the matrix, the method may also be applicable to higher concentrations ranging from 1 µg/l to 100 µg/l after suitable dilution of the sample or reduction in sample size.
Edition
1
Published Date
2018-06-12
Status
PUBLISHED
Pages
23
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a method for the quantitative determination of selected cyclic volatile methylsiloxanes (cVMS) in non-filtered water samples by purge and trap extraction with isotope dilution gas chromatography-mass spectrometry (GC-MS).
This method is applicable to the determination of individual cVMS, including:
- octamethylcyclotetrasiloxane (D4);
- decamethylcyclopentasiloxane (D5);
- dodecamethylcyclohexasiloxane (D6);
in surface water, ground water, and wastewater. It can be applied to samples within the concentration range of 0,01 µg/l to 1 µg/l of each of the target compounds. Depending on the matrix, the method may also be applicable to higher concentrations ranging from 1 µg/l to 100 µg/l after suitable dilution of the sample or reduction in sample size.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 15681:2003 Water quality – Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) – Part 1: Method by flow injection analysis (FIA)
CDN $251.00 Add to cart -

ISO 9964:1993 Water quality – Determination of sodium and potassium – Part 1: Determination of sodium by atomic absorption spectrometry
CDN $82.00 Add to cart -

ISO 22066:2020 Water quality – Determination of total cyanide – Method using segmented flow injection, in-line ultraviolet digestion analysis by gas diffusion and amperometric detection
CDN $186.00 Add to cart -

ISO 21675:2019 Water quality – Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water – Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
CDN $336.00 Add to cart