Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 20804:2022

ISO 20804:2022 Determination of the specific surface area of porous and particulate systems by small-angle X-ray scattering (SAXS)

CDN $233.00

SKU: 764cdff6a28b Category:

Description

This document specifies the application of small-angle X-ray scattering (SAXS) for the determination of specific surface area. Both the mass specific surface area in the order of 1 m2g-1 to 2 000 m2g-1 and the volume specific surface areas in the range from 0,01 m2cm-3 to 1 000 m2cm-3 can be obtained.

The method described is applicable to dilute and concentrated systems.

NOTE:      In ISO 17867:2020, the determination of the particle size by SAXS is limited to dilute systems.

The determination of surfaces with SAXS is straightforward for two-phase systems only. Surface determination in systems with more than two phases is beyond the scope of this document.

The term ‘surface’ refers to any interface between domains of different density (more precisely: electron density) and is not restricted to the external surface of particles. As any interfaces between areas with different electron density, not only to air or vacuum, can be probed, the method can be applied to any heterogeneous system.

SAXS measures not only the specific surface area of open pores but also of inaccessible, closed pores or inclusions.

NOTE:      This is in contrast to gas sorption methods which are described in ISO 9277:2010.

In addition to porous systems, there can be contributions of internal interfaces to the measured specific surface area of any heterogeneous compact solid system, such as between crystalline and amorphous phases, provided there is an electron density contrast. Although materials comprising micropores (pore width < 2 nm) can also be analysed with respect to their specific surface area with SAXS, this document does not cover these materials.

Edition

1

Published Date

2022-05-27

Status

PUBLISHED

Pages

22

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the application of small-angle X-ray scattering (SAXS) for the determination of specific surface area. Both the mass specific surface area in the order of 1 m2g-1 to 2 000 m2g-1 and the volume specific surface areas in the range from 0,01 m2cm-3 to 1 000 m2cm-3 can be obtained.

The method described is applicable to dilute and concentrated systems.

NOTE:      In ISO 17867:2020, the determination of the particle size by SAXS is limited to dilute systems.

The determination of surfaces with SAXS is straightforward for two-phase systems only. Surface determination in systems with more than two phases is beyond the scope of this document.

The term ‘surface’ refers to any interface between domains of different density (more precisely: electron density) and is not restricted to the external surface of particles. As any interfaces between areas with different electron density, not only to air or vacuum, can be probed, the method can be applied to any heterogeneous system.

SAXS measures not only the specific surface area of open pores but also of inaccessible, closed pores or inclusions.

NOTE:      This is in contrast to gas sorption methods which are described in ISO 9277:2010.

In addition to porous systems, there can be contributions of internal interfaces to the measured specific surface area of any heterogeneous compact solid system, such as between crystalline and amorphous phases, provided there is an electron density contrast. Although materials comprising micropores (pore width < 2 nm) can also be analysed with respect to their specific surface area with SAXS, this document does not cover these materials.

Previous Editions

Can’t find what you are looking for?

Please contact us at: