Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 20890:2020

ISO 20890:2020 Guidelines for in-service inspections for primary coolant circuit components of light water reactors – Part 1: Mechanized ultrasonic testing

CDN $273.00

SKU: 1850e69a2244 Category:

Description

This document gives guidelines for pre-service-inspections (PSI) and in-service inspections (ISI) with mechanized ultrasonic test (UT) devices on components of the reactor coolant circuit of light water reactors. This document is also applicable on other components of nuclear installations.

Mechanized ultrasonic inspections are carried out in order to enable an evaluation in case of

– fault indications (e.g. on austenitic weld seams or complex geometry),

– indications due to geometry (e.g. in case of root concavity),

– complex geometries (e.g. fitting weld seams), or

– if a reduction in the radiation exposure of the test personnel can be attained in this way.

Ultrasonic test methods are defined for the validation of discontinuities (volume or surface open), requirements for the ultrasonic test equipment, for the preparation of test and device systems, for the implementation of the test and for the recording.

This document is applicable for the detection of indications by UT using normal-beam probes and angle-beam probes both in contact technique. It is to be used for UT examination on ferritic and austenitic welds and base material as search techniques and for comparison with acceptance criteria by the national referencing nuclear safety standards. Immersion technique and techniques for sizing are not in the scope of this document and are independent qualified.

NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the applicable national nuclear safety standards.

Unless otherwise specified in national nuclear safety standards the minimum requirements of this document are applicable. This document does not define:

– extent of examination and scanning plans;

– acceptance criteria;

– UT techniques for dissimilar metal welds and for sizing (have to be qualified separately);

– immersion techniques;

– time-of-flight diffraction technique (TOFD).

It is recommended that UT examinations are nearly related to the component, the type and size of defects to be considered and are reviewed in specific national inspection qualifications.

Edition

1

Published Date

2020-06-12

Status

PUBLISHED

Pages

33

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document gives guidelines for pre-service-inspections (PSI) and in-service inspections (ISI) with mechanized ultrasonic test (UT) devices on components of the reactor coolant circuit of light water reactors. This document is also applicable on other components of nuclear installations.

Mechanized ultrasonic inspections are carried out in order to enable an evaluation in case of

- fault indications (e.g. on austenitic weld seams or complex geometry),

- indications due to geometry (e.g. in case of root concavity),

- complex geometries (e.g. fitting weld seams), or

- if a reduction in the radiation exposure of the test personnel can be attained in this way.

Ultrasonic test methods are defined for the validation of discontinuities (volume or surface open), requirements for the ultrasonic test equipment, for the preparation of test and device systems, for the implementation of the test and for the recording.

This document is applicable for the detection of indications by UT using normal-beam probes and angle-beam probes both in contact technique. It is to be used for UT examination on ferritic and austenitic welds and base material as search techniques and for comparison with acceptance criteria by the national referencing nuclear safety standards. Immersion technique and techniques for sizing are not in the scope of this document and are independent qualified.

NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the applicable national nuclear safety standards.

Unless otherwise specified in national nuclear safety standards the minimum requirements of this document are applicable. This document does not define:

- extent of examination and scanning plans;

- acceptance criteria;

- UT techniques for dissimilar metal welds and for sizing (have to be qualified separately);

- immersion techniques;

- time-of-flight diffraction technique (TOFD).

It is recommended that UT examinations are nearly related to the component, the type and size of defects to be considered and are reviewed in specific national inspection qualifications.

Previous Editions

Can’t find what you are looking for?

Please contact us at: