
ISO 20998:2017
ISO 20998:2017 Measurement and characterization of particles by acoustic methods – Part 3: Guidelines for non-linear theory
CDN $233.00
Description
ISO 20998-3:2017 gives guidelines for ultrasonic attenuation spectroscopy methods for determining the size distributions of one or more material phases dispersed in a liquid at high concentrations, where the ultrasonic attenuation spectrum is not a linear function of the particle volume fraction. In this regime, particle-particle interactions are not negligible.
ISO 20998-3:2017 is applicable to colloids, dispersions, slurries, and emulsions. The typical particle size for such analysis ranges from 10 nm to 3 mm, although particles outside this range have also been successfully measured. Measurements can be made for concentrations of the dispersed phase ranging from about 5 % by volume to over 50 % by volume, depending on the density contrast between the continuous and the dispersed phases, the particle size, and the frequency range[9] [10]. These ultrasonic methods can be used to monitor dynamic changes in the size distribution, including agglomeration or flocculation.
Edition
1
Published Date
2017-04-21
Status
PUBLISHED
Pages
24
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 20998-3:2017 gives guidelines for ultrasonic attenuation spectroscopy methods for determining the size distributions of one or more material phases dispersed in a liquid at high concentrations, where the ultrasonic attenuation spectrum is not a linear function of the particle volume fraction. In this regime, particle-particle interactions are not negligible.
ISO 20998-3:2017 is applicable to colloids, dispersions, slurries, and emulsions. The typical particle size for such analysis ranges from 10 nm to 3 mm, although particles outside this range have also been successfully measured. Measurements can be made for concentrations of the dispersed phase ranging from about 5 % by volume to over 50 % by volume, depending on the density contrast between the continuous and the dispersed phases, the particle size, and the frequency range[9] [10]. These ultrasonic methods can be used to monitor dynamic changes in the size distribution, including agglomeration or flocculation.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 2574:1994 Aircraft – Electrical cables – Identification marking
CDN $115.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $76.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 8: Nanomanufacturing processes
CDN $76.00 Add to cart -

ISO 5053:2019 Industrial trucks – Vocabulary – Part 2: Fork arms and attachments
CDN $351.00 Add to cart







