Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 21397:2021

ISO 21397:2021 FTIR analysis of fire effluents in cone calorimeter tests

CDN $115.00

SKU: d3e339b0155b Categories: ,

Description

This document specifies a method for determining the kinetics and yields of gaseous emissions from a specimen exposed to radiant heat in a cone calorimeter. Gas yields are determined by exposing small representative specimens to an external heat flux with or without spark ignition. The concentrations of specific gases in the effluent (smoke) are measured. In combination with calculated masses of gases, their yields from the specimen mass, mass loss or mass loss rate can be determined. This document uses Fourier-Transform Infrared (FTIR) spectroscopy as described in ISO 19702, with additional information on the test apparatus and gas analyser suitable for this specific application.

Edition

1

Published Date

2021-03-09

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for determining the kinetics and yields of gaseous emissions from a specimen exposed to radiant heat in a cone calorimeter. Gas yields are determined by exposing small representative specimens to an external heat flux with or without spark ignition. The concentrations of specific gases in the effluent (smoke) are measured. In combination with calculated masses of gases, their yields from the specimen mass, mass loss or mass loss rate can be determined. This document uses Fourier-Transform Infrared (FTIR) spectroscopy as described in ISO 19702, with additional information on the test apparatus and gas analyser suitable for this specific application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: