ISO 21501:2009

ISO 21501:2009 Determination of particle size distribution – Single particle light interaction methods – Part 1: Light scattering aerosol spectrometer

CDN $295.00

SKU: 3a35417979e5 Categories: ,

Description

ISO 21501-1:2009 specifies characteristics of a light scattering aerosol spectrometer (LSAS) which is used for measuring the size, number concentration and number/size distribution of particles suspended in a gas. The light scattering technique described in this document is based upon single particle measurements. The size range of particles measured by this method is between approximately 0,06 µm to 45 µm in diameter.

Instruments that conform to ISO 21501-1:2009 are used for the determination of the particle size distribution and particle number concentration at relatively high concentrations of up to 1011 particles/m3.

Application fields include: characterization of metered dose inhalers (MDI), dry powder inhalers (DPI) and nebulizers in pharmacy; production control of active agents; cut-off determination: impactors, cyclones and impingers; atmospheric aerosols: bio-aerosols, stables/composting facilities, nebulized droplets, measurements in street tunnels; fractional separation efficiency determination of filters.

For the above-mentioned applications, aerosol spectrometers should determine the particle size distribution, particle number concentration, size resolution and sizing accuracy as accurately as possible. These aerosol spectrometers are not suitable for the classification of clean rooms.

Edition

1

Published Date

2009-05-22

Status

PUBLISHED

Pages

27

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 21501-1:2009 specifies characteristics of a light scattering aerosol spectrometer (LSAS) which is used for measuring the size, number concentration and number/size distribution of particles suspended in a gas. The light scattering technique described in this document is based upon single particle measurements. The size range of particles measured by this method is between approximately 0,06 µm to 45 µm in diameter.

Instruments that conform to ISO 21501-1:2009 are used for the determination of the particle size distribution and particle number concentration at relatively high concentrations of up to 1011 particles/m3.

Application fields include: characterization of metered dose inhalers (MDI), dry powder inhalers (DPI) and nebulizers in pharmacy; production control of active agents; cut-off determination: impactors, cyclones and impingers; atmospheric aerosols: bio-aerosols, stables/composting facilities, nebulized droplets, measurements in street tunnels; fractional separation efficiency determination of filters.

For the above-mentioned applications, aerosol spectrometers should determine the particle size distribution, particle number concentration, size resolution and sizing accuracy as accurately as possible. These aerosol spectrometers are not suitable for the classification of clean rooms.