ISO 21501:2018

ISO 21501:2018 Determination of particle size distribution – Single particle light interaction methods – Part 4: Light scattering airborne particle counter for clean spaces

CDN $263.00

SKU: 6e8aa60c9d50 Categories: ,

Description

This document describes a calibration and verification method for a light scattering airborne particle counter (LSAPC), which is used to measure the size distribution and particle number concentration of particles suspended in air. The light scattering method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 0,1 μm and 10 μm in particle size.

Instruments that conform to this document are used for the classification of air cleanliness in cleanrooms and associated controlled environments in accordance with ISO 14644‚Äë1 and ISO 14644‚Äë2, as well as the measurement of number and size distribution of particles in various environments.

The following parameters are within the scope of this document:

– size setting error;

– counting efficiency;

– size resolution;

– false count;

– maximum particle number concentration;

– sampling flow rate error;

– sampling time error;

– response rate;

– calibration interval;

– reporting results from test and calibration.

Edition

2

Published Date

2018-05-18

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document describes a calibration and verification method for a light scattering airborne particle counter (LSAPC), which is used to measure the size distribution and particle number concentration of particles suspended in air. The light scattering method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 0,1 μm and 10 μm in particle size.

Instruments that conform to this document are used for the classification of air cleanliness in cleanrooms and associated controlled environments in accordance with ISO 14644‚Äë1 and ISO 14644‚Äë2, as well as the measurement of number and size distribution of particles in various environments.

The following parameters are within the scope of this document:

- size setting error;

- counting efficiency;

- size resolution;

- false count;

- maximum particle number concentration;

- sampling flow rate error;

- sampling time error;

- response rate;

- calibration interval;

- reporting results from test and calibration.