ISO 21524:2021
ISO 21524:2021 Fire resistance tests – Elements of building construction – Requirements for active fire curtains
CDN $390.00
Description
This document specifies requirements for the design, testing and classification of active fire curtains, applicable to any material, that are designed to provide fire and smoke resistance.
This document gives recommendations for the application, installation and maintenance of active fire curtains. It is also intended to provide guidance and recommendations for designers, specifiers (e.g. architects, fire engineers), authorities having jurisdiction (AHJs), installers and maintainers for the following:
a) creating compartmentation;
b) creating protected routes for the purpose of means of escape;
c) providing protection at the location of non-fire resisting elements (e.g. in front of non-fire-resisting glazing and doorsets) where required for compartmentation or protecting means of escape;
d) providing fire- and smoke-resistant active fire curtains in conjunction with non-smoke rated products protecting openings to reduce leakage of smoke.
This document does not apply to the following, which are intended for a different use:
-   barriers made of part of the building’s structure;
-   theatre/proscenium textile curtains;
-   smoke barriers according to ISO 21927-1;
-   door and shutter assemblies according to ISO 3008‑1.
NOTE 1   Smoke barriers used solely for smoke control are covered by ISO 21927‑1. Such smoke barriers are not considered to be active fire curtains.
NOTE 2   Requirements of fire doors are given in ISO 3008-1. Requirements for leakage are given in ISO 5925‑1 and further information is given in ISO/TR 5925‑2.
Edition
1
Published Date
2021-07-05
Status
PUBLISHED
Pages
114
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies requirements for the design, testing and classification of active fire curtains, applicable to any material, that are designed to provide fire and smoke resistance.
This document gives recommendations for the application, installation and maintenance of active fire curtains. It is also intended to provide guidance and recommendations for designers, specifiers (e.g. architects, fire engineers), authorities having jurisdiction (AHJs), installers and maintainers for the following:
a) creating compartmentation;
b) creating protected routes for the purpose of means of escape;
c) providing protection at the location of non-fire resisting elements (e.g. in front of non-fire-resisting glazing and doorsets) where required for compartmentation or protecting means of escape;
d) providing fire- and smoke-resistant active fire curtains in conjunction with non-smoke rated products protecting openings to reduce leakage of smoke.
This document does not apply to the following, which are intended for a different use:
-   barriers made of part of the building’s structure;
-   theatre/proscenium textile curtains;
-   smoke barriers according to ISO 21927-1;
-   door and shutter assemblies according to ISO 3008‑1.
NOTE 1   Smoke barriers used solely for smoke control are covered by ISO 21927‑1. Such smoke barriers are not considered to be active fire curtains.
NOTE 2   Requirements of fire doors are given in ISO 3008-1. Requirements for leakage are given in ISO 5925‑1 and further information is given in ISO/TR 5925‑2.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 9705:2016 Reaction to fire tests – Room corner test for wall and ceiling lining products – Part 1: Test method for a small room configuration
CDN $312.00 Add to cart -

ISO 23657:2022 Reaction to fire test for sandwich panel building systems – Intermediate-scale box test
CDN $173.00 Add to cart -

ISO 3008:2019 Fire resistance tests – Door and shutter assemblies – Part 1: General requirements
CDN $351.00 Add to cart -

ISO 13784:2020 Reaction-to-fire tests for sandwich panel building systems – Part 2: Test method for large rooms
CDN $173.00 Add to cart