Search
×
FR

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 21316:2026 Traditional Chinese medicine — Isatis indigotica root

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

TEMA 11th Edition – Book of Standards (Not for Resale)

$

0

BUY NOW

ISO 21925:2021

ISO 21925:2021 Fire resistance tests – Fire dampers for air distribution systems – Part 2: Intumescent dampers

CDN $352.00

SKU: 3c864d701931 Categories: ,

Description

This document specifies a test method for the determination of the resistance of fire dampers to heat, and for the evaluation of their ability to prevent fire and smoke from spreading from one fire compartment to another through an air distribution system.

This document describes the test requirements related to intumescent fire dampers. It is intended for intumescent fire dampers that are expected to be classified as EI dampers. Without the addition of a mechanical damper, they are unable to achieve the “S” classification, which includes a leakage limit imposed at ambient temperature.

This document is not intended to be used for dampers used only in smoke control systems, for testing fire protection devices which only deal with air transfer applications, or for dampers used in suspended ceilings, as the installation of the damper and duct can have an adverse effect on the performance of the suspended ceiling, requiring other methods of evaluation.

NOTE¬†¬†¬†¬†¬†¬† “Air transfer” is a low-pressure application through a fire separation door (or wall, floor) without any connection to an air duct.

Edition

1

Published Date

2021-06-25

Status

PUBLISHED

Pages

44

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a test method for the determination of the resistance of fire dampers to heat, and for the evaluation of their ability to prevent fire and smoke from spreading from one fire compartment to another through an air distribution system.

This document describes the test requirements related to intumescent fire dampers. It is intended for intumescent fire dampers that are expected to be classified as EI dampers. Without the addition of a mechanical damper, they are unable to achieve the “S” classification, which includes a leakage limit imposed at ambient temperature.

This document is not intended to be used for dampers used only in smoke control systems, for testing fire protection devices which only deal with air transfer applications, or for dampers used in suspended ceilings, as the installation of the damper and duct can have an adverse effect on the performance of the suspended ceiling, requiring other methods of evaluation.

NOTE       "Air transfer" is a low-pressure application through a fire separation door (or wall, floor) without any connection to an air duct.

Previous Editions

Can’t find what you are looking for?

Please contact us at: